IBM 7940 Problem Determination And Service Manual page 132

Ibm system x3455 type 7940 and 7941
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 7940 and 7941 servers," on page 19 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
BMC log message
PS 1 Fan Fault Asserted
PS 1 Fan Fault Deasserted
PS 1 Thermal Fault Asserted
PS 1 Thermal Fault Deasserted
CPU 1 Prochot Asserted
CPU 2 Prochot Asserted
CPU 1 Prochot Deasserted
CPU 2 Prochot Deasserted
System Power off Asserted
System Power off Deasserted
SEL 100% Full Asserted
SEL over 90% Full Asserted
SEL over 75% Full Asserted
SEL 100% Full Deasserted
SEL over 90% Full Deasserted
SEL over 75% Full Deasserted
CPU 1 DIMM 1A DIMM Single-Bit Error
CPU 1 DIMM 1B DIMM Single-Bit Error
CPU 1 DIMM 2A DIMM Single-Bit Error
CPU 1 DIMM 2B DIMM Single-Bit Error
CPU 1 DIMM 3A DIMM Single-Bit Error
CPU 1 DIMM 3B DIMM Single-Bit Error
CPU 2 DIMM 1A DIMM Single-Bit Error
CPU 2 DIMM 1B DIMM Single-Bit Error
CPU 2 DIMM 2A DIMM Single-Bit Error
CPU 2 DIMM 2B DIMM Single-Bit Error
CPU 2 DIMM 3A DIMM Single-Bit Error
CPU 2 DIMM 3B DIMM Single-Bit Error
114
IBM System x3455 Type 7940 and 7941: Problem Determination and Service Guide
Sensor
Sensor
type
number
04h
73h
04h
73h
08h
77h
08h
77h
07h
C0h
07h
C1h
07h
C0h
07h
C1h
09h
01h
09h
01h
B6h
01h
B6h
01h
B6h
01h
B6h
01h
B6h
01h
B6h
01h
0Ch
00h
0Ch
00h
0Ch
00h
0Ch
00h
0Ch
00h
0Ch
00h
0Ch
00h
0Ch
00h
0Ch
00h
0Ch
00h
0Ch
00h
0Ch
00h
Action
1. Make sure that there are no obstructions,
such as bundled cables, to the airflow on
the power-supply fan.
2. (Trained service technician only) Replace
the power supply.
Information only
Information only
Information only
1. Make sure that the fans are operating,
that there are no obstructions to the
airflow, that the air baffles are in place and
correctly installed, and that the server
cover is installed and completely closed.
2. (Trained service technician only) Make
sure that the heat sink for CPU n is
installed correctly.
3. (Trained service technician only) Replace
CPU n.
4. (Trained service technician only) Replace
the system board.
Information only
Information only
Information only
Information only
Information only
Information only

Advertisement

Table of Contents
loading

This manual is also suitable for:

7941