Table 2 Inverter Mode Specifications - MPP Solar PIP-HS User Manual

1-5kva inverter/charger
Hide thumbs Also See for PIP-HS:
Table of Contents

Advertisement

Table 2 Inverter Mode Specifications

INVERTER MODEL
Rated Output Power
Output Voltage Waveform
Output Voltage Regulation
Output Frequency
Peak Efficiency
Overload Protection
Surge Capacity
Nominal DC Input Voltage
Cold Start Voltage
Low DC Warning Voltage
@ load < 20%
@ 20% ≤ load < 50%
@ load ≥ 50%
Low DC Warning Return Voltage
@ load < 20%
@ 20% ≤ load < 50%
@ load ≥ 50%
Low DC Cut-off Voltage
@ load < 20%
@ 20% ≤ load < 50%
@ load ≥ 50%
High DC Recovery Voltage
High DC Cut-off Voltage
No Load Power Consumption
Saving Mode Power Consumption
1KVA
2KVA
1KVA/0.8KW 2KVA/1.6KW 3KVA/2.4KW 4KVA/3.2KW 5KVA/4KW
5s@≥150% load; 10s@110%~150% load
2* rated power for 5 seconds
12Vdc
11.5Vdc
23.0Vdc
11.0Vdc
22.0Vdc
10.7Vdc
21.4Vdc
10.1Vdc
20.2Vdc
11.5Vdc
23.0Vdc
11.2Vdc
22.4Vdc
10.6Vdc
21.2Vdc
10.5Vdc
21.0Vdc
10.2Vdc
20.4Vdc
9.6Vdc
19.2Vdc
14.5Vdc
15.5Vdc
<15W
<5W
29
3KVA
4KVA
Pure Sine Wave
230Vac± 5%
50Hz
90%
24Vdc
29Vdc
31Vdc
<20W
<10W
5KVA
48Vdc
46.0Vdc
44.0Vdc
42.8Vdc
40.4Vdc
46.0Vdc
44.8Vdc
42.4Vdc
42.0Vdc
40.8Vdc
38.4Vdc
58Vdc
60Vdc
<50W
<15W

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents