Maximum Power (Pmax)
Max. Power Voltage Vmpp(V)
Max. Power Current Impp(A)
Open Circuit Voltage Voc(V)
Short Circuit Current Isc(A)
Maximum PV module numbers in Series: 1
PV module numbers in Parallel: 6
Total PV module numbers: 1 x 6 = 6
Take 4K/5K model inverter as an example to select proper PV module. After considering Voc of PV module not
exceed 105Vdc and max. Vmpp of PV module close to 60Vdc or within 56Vdc ~ 72Vdc, we can choose PV
module with below specification.
Maximum Power (Pmax)
Max. Power Voltage Vmpp(V)
Max. Power Current Impp(A)
Open Circuit Voltage Voc(V)
Short Circuit Current Isc(A)
Maximum PV module numbers in Series: 2
PV module numbers in Parallel: 6
Total PV module numbers: 2 x 6 = 12
Please follow below steps to implement PV module connection:
1. Remove insulation sleeve 10 mm for positive and negative conductors.
2. Check correct polarity of connection cable from PV modules and PV input
connectors. Then, connect positive pole (+) of connection cable to positive
pole (+) of PV input connector. Connect negative pole (-) of connection
cable to negative pole (-) of PV input connector.
3. Make sure the wires are securely connected.

Final Assembly

After connecting all wirings, please put bottom cover back by screwing two screws as shown below.
260W
Max. PV module numbers in series
30.9V
1  30.9 x 1 ≒ 30 ~ 32
8.42A
PV module numbers in parallel
6  50 A / 8.42
37.7V
Total PV module numbers
8.89A
1 x 6 = 6
260W
Max. PV module numbers in series
2  30.9 x 2 ≒ 56 ~ 72
30.9V
8.42A
PV module numbers in parallel
6  50 A / 8.42
37.7V
Total PV module numbers
8.89A
2 x 6 = 12
1~3KVA
10
4~5KVA