Insert plug-in
cards
- Set the AC and DC disconnect to the OFF position
- open connection area - see section titled "Connection"
Important! In dealing with plug-in cards observe the general ESD regula-
tions
- Insert card (2) into one of the slots of the control board.
- Tighten card (2) with fastening screw (1). A small metal plate is provi-
- Insert a 1/2 or 3/4 in. conduit fitting in the knockout (3) labeled "Dat-
- Insert DatCom cables (see manual FRONIUS IG DatCom through the
- Close the connection area
- Set the AC and DC disconnects to the ON position.
WARNING! Hazard due to supply voltage and DC-voltage from the
solar modules. Only qualified electrical professionals are authorized
to open the connection area and only when the inverter is not under
voltage.
NOTE! The COM Card should be inserted in the slot named
"ENS".
ded as a tool with the COM Card.
Com" and fasten it.
NOTE! Only use water tight conduits for the AC, DC and the optio-
nal DatCom knockouts.
DatCom conduit and connect them to the sockets "IN" and "OUT"
Prefereably insert COM-
Card into the left-most slot
(3)
57
(2)
(1)
(3)
Insert any of the following cards
in option slot 1 or 2:
- Datalogger Card
- Personal Display Card
- Interface Card easy
- Sensor Card