14.4.3) Check valve
Effectivity: 912 Series
Edition 1 / Rev. 0
BRP-Rotax
INSTALLATION MANUAL
1
Fig. 56
00537
9
10
Specification:
opening pressure ...................................... 0,1-0,15 bar
permitted pressure in reverse-biasing ....... 2 bar (29 psi.)
burst pressure ........................................... 5 bar (72,5 psi.)
14
15
2
Fig. 57
02064
12
13
(1,5 psi. - 2,2 psi.)
page 89