The only two valid fan configurations are listed in the following table.
Configuration
Fan bay 1 Fan bay 2 Fan bay 3
Fan blank
1 processor
Fan
2 processors
For a single-processor configuration, five fans and two blanks are required in specific fan bays for
redundancy.
For a dual-processor configuration, seven fans are required for redundancy. A fan failure or missing fan
causes a loss of redundancy. A second fan failure or missing fan causes an orderly shutdown of the server.
The high performance fan option might be necessary for the following installations:
LR DIMM configuration
ASHRAE compliant configurations
For more information, see the HP website (http://www.hp.com/servers/ASHRAE).
The server supports variable fan speeds. The fans operate at minimum speed until a temperature change
requires a fan speed increase to cool the server. The server shuts down during the following
temperature-related scenarios:
At POST and in the OS, HP iLO performs an orderly shutdown if a cautionary temperature level is
detected. If the server hardware detects a critical temperature level before an orderly shutdown occurs,
the server performs an immediate shutdown.
When the Thermal Shutdown feature is disabled in RBSU, HP iLO does not perform an orderly shutdown
when a cautionary temperature level is detected. Disabling this feature does not disable the server
hardware from performing an immediate shutdown when a critical temperature level is detected.
CAUTION:
A thermal event can damage server components when the Thermal Shutdown feature
is disabled in RBSU.
Fan blank
Fan
Fan
Fan
Fan bay 4 Fan bay 5 Fan bay 6
Fan
Fan
Fan
Fan
Fan
Fan
Component identification 19
Fan bay 7
Fan
Fan