Superior BXI2518MN Installation And Operation Instructions Manual

B-vent gas stoves millivolt system

Advertisement

Quick Links

P127116 01
P/N 127116-01 Rev A 05/2014
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
WARNING AVERTISSEMENT AVISO
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
PFS
®
US
Report No. 09-170
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
UNE SURFACE VITRÉE CHAUDE PEUT
CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE VITRÉE
AVANT D'Y TOUCHER.
NE PERMETTEZ JAMAIS À UN ENFANT DE
TOUCHER LA SURFACE VITRÉE.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d'incindie ou d'explosion ou pour éviter
tout dommage matériel, toute blessure ou la mort.
— Ne pas entreposer ni utilizer d'essence ni d'autres
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
— L'installation et l'entretien doivent être assurés par un
For more information, visit www.Superiorfireplaces.US.com
Installation and Operation Instructions
Superior™ B-Vent Gas Stoves
Millivolt System
BXI2518MN
BXI2518MP
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâtiment
où vous trouvez.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
Models
EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
USTED DEBE NUNCA TOCAR
EL VIDRIO CALIENTE.
LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BXI2518MN and is the answer not in the manual?

Questions and answers

Summary of Contents for Superior BXI2518MN

  • Page 1 Installation and Operation Instructions Superior™ B-Vent Gas Stoves Millivolt System Models BXI2518MN BXI2518MP ® P127116 01 P/N 127116-01 Rev A 05/2014 Report No. 09-170 INSTALLER: Leave this manual with the appliance. Installateur : Laissez cette notice avec l’appareil. CONSUMER: Retain this manual for future reference.
  • Page 2: Table Of Contents

    Thank you for your purchase. We appreciate your TABLE OF CONTENTS business! Safety .....................2 Please carefully read and follow all instructions in this manual. Pay Local Codes ...................4 special attention to all warnings and safety information. Product Features ................4 Following these safety, care, and operation instructions will help Product Identification ..............4 ensure many years of dependable and enjoyable service from your Pre-Installation Preparation ............5...
  • Page 3 SAFETY Continued Do not use this stove to cook food or burn paper or DANGER: Carbon monoxide poisoning may lead other flammable material. to death! This stove complies with the National Safety Standards and is listed This stove reaches high temperatures. Keep children and tested by PFS Corporation to ANSI Z21.50 standard as vented and adults away from hot surface to avoid burns or gas stove.
  • Page 4: Local Codes

    LOCAL CODES SAFETY Continued Install and use stove and burner system with care. Follow all local 10. Do not operate burner system if any log is broken. codes. In the absence to local codes, use the current National Fuel 11. Do not operate burner system with glass door removed, cracked Gas Code ANSI Z223.1/NFPA 54* or broken.
  • Page 5: Preinstallation Preparation

    PREINSTALLATION PREPARATION Ceiling WARNING: A qualified installer or service person must install stove and burner system. Follow all lo- cal codes. 42" CAUTION: This stove with burner system creates warm air currents. These currents move heat to wall surfaces next to stove. Installing stove next to vinyl or cloth wall coverings or operating stove with burner system where impurities (such as, but not limited to, 36"...
  • Page 6: Unpacking

    UNPACKING Top of Wood 1. Lift off corrugated box enclosing stove body crating. Frame Enclosure 2. Remove screws fastening back and top of wood frame enclosure. STOVE TOP Two or more people must carefully lift stove up and out of wooden crate.
  • Page 7 VENTING INSTALLATION Continued INSTALLATION OF LISTED B-1 VENT Round WARNING: Installation should only be made by Storm Collar qualified persons who are familiar with the safety procedures required for the installation of the product, Flashing Roof who are equipped with the proper tools and testing Support instruments, and who have achieved proper certifica- tion of licensing.
  • Page 8 VENTING INSTALLATION Continued INSTALLING VENT SYSTEM INTO CHASE A chase is a vertical box-like structure built to enclose venting that runs along the outside of a building. A chase is not required for such venting. NOTICE: Treatment of firestops and construction of the chase may vary from building type to building type.
  • Page 9 VENTING INSTALLATION Continued CHIMNEYS • Complete familiarity with chimney condition, height, size, clearance to combustibles and other factors is essential. NOTICE: Consult the authority having jurisdiction in your area regarding masonry chimney venting applications. NOTICE: A complete chimney inspection by a qualified person should be performed.
  • Page 10 VENTING INSTALLATION Continued HIGH ALTITUDE INSTALLATION Elbows Too many elbows cause excessive restriction of flow and may result Your IHP B-vent burner system has been tested and approved for in spillage. Usually, two 90º turns can be tolerated in a properly sized operation at altitudes in the USA from 0-2000 feet.
  • Page 11: Installation

    INSTALLATION NOTICE: This burner system is intended for use as For propane/LP connections only, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. supplemental heat. Use this burner system along with You must reduce incoming gas pressure to between 11" and 14" of your primary heating system.
  • Page 12 INSTALLATION Continued CHECKING GAS CONNECTIONS Equipment Shutoff Valve with 1/8" NPT Tap* Natural - From WARNING: Test all gas piping and connections, Gas Meter (5" internal and external to unit, for leaks after installing W.C. to 10.5" or servicing. Correct all leaks at once. W.C.
  • Page 13 INSTALLATION Continued Equipment INSTALLING OPTIONAL WALL MOUNT SWITCH - GWMS2 Shutoff Valve Propane/ 1. Connect one terminal of 25 ft. wire for the wall switch to the TPTH LP Supply terminal on the valve. Connect remaining wire terminal to the TH Tank terminal on the valve.
  • Page 14 INSTALLATION Continued BURNER SYSTEM ASSEMBLY REMOVING/REPLACING GLASS DOOR INSTALLING B-VENT BURNER SYSTEM INTO STOVE BODY 1. Carefully lift burner system and place into stove body from the rear of stove. 2. Discard center grate top of stove and replace with center grate top provided with Cast Iron Stove Body.
  • Page 15 INSTALLATION Continued INSTALLING LOGS, LAVA ROCK, AND GLOWING EMBERS WARNING: Failure to position the parts in ac- cordance with these diagrams or failure to use only parts specifically approved with this burner system may result in property damage or personal injury. It is very important to install these logs exactly as instructed in Fig- ures 24 through 28.
  • Page 16: Operation

    INSTALLATION Continued OPERATION 6. Lava rock may be placed along sides and front inside burner FOR YOUR SAFETY system bottom. This may not be visible when you have replaced READ BEFORE LIGHTING the front of stove. It is not necessary to use all of the lava rock provided.
  • Page 17 OPERATION Continued 10. Turn gas control counterclockwise to ON. OPTIONAL REMOTE 11. Turn on all electric power to the burner system. OPERATION 12. Turn the ON/OFF switch to ON position. Note: All remote control accessories must be purchased separately 13. Close lower panel. (see Accessories, page 26).
  • Page 18: Inspecting Burners

    INSPECTING BURNERS BURNER FLAME PATTERN Check pilot flame pattern and burner flame patterns often. Burner flames will be steady; not lifting or floating. Flame patterns will PILOT ASSEMBLY be different from unit to unit and will vary depending on installation The pilot assembly is factory preset for the proper flame height.
  • Page 19: Cleaning And Maintenance

    CLEANING AND MAINTENANCE PILOT AND BURNERS WARNING: Turn off burner system and let cool • Remove ember material before cleaning burners and replace when before cleaning. cleaning is complete. • Burner and controls should be cleaned with compressed air to remove dust, dirt, or lint.
  • Page 20: Troubleshooting

    TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY...
  • Page 21 TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Burner does not light after pilot is lit. 1. Burner orifice clogged. 1. Clean burner (see Cleaning and Mainte- nance, page 19) or replace burner orifice. 2. Contact local propane/LP or natural gas 2.
  • Page 22 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. •...
  • Page 23: Specifications

    3. Burner flame holes blocked. 4. Follow venting configuration instructions 4. Improper vent configuration on pages 6 thru 10. SPECIFICATIONS BXI2518MN BXI2518MP • Rating: 30,000 Btu/Hr • Rating: 28,000 Btu/Hr • Gas Type: Natural Gas • Gas Type: Propane/LP Gas •...
  • Page 24: Parts

    PARTS MODELS BXI2518MN, BXI2518MP 23-3 23-1 23-4 23-2 www.Superiorfireplaces.US.com 127116-01A...
  • Page 25 PARTS MODELS BXI2518MN, BXI2518MP This list contains replaceable parts used in your burner system. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual. KEY NO. PART NO. DESCRIPTION QTY. Firebox Assembly 105795-01 Glass Door Assembly...
  • Page 26: Service Hints

    SERVICE HINTS TECHNICAL SERVICE When Gas Pressure is Too Low: You may have further questions about installation, operation, • pilot will not stay lit or troubleshooting. If so, contact IHP at 1-800-655-2008 When calling please have your model and serial numbers of your heater •...
  • Page 27: Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 28 WARRANTY KEEP THIS WARRANTY Model (located on product or id tag) Burner System _________ Cast Stove ___________ Serial No. (located on product or identification tag) ___________________ Date Purchased ______________________ Keep receipt for warranty verification. Innovative Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

This manual is also suitable for:

Bxi2518mp

Table of Contents