CHIMNEYS
• Complete familiarity with chimney condition, height, size, clearance
to combustibles and other factors is essential.
NOTICE: Consult the authority having jurisdiction
in your area regarding masonry chimney venting
applications.
NOTICE: A complete chimney inspection by a qualified
person should be performed.
• Appliances using B-vent connectors to vent into a masonry or factory-
built chimney should not exceed 1
connector diameter (3" vent connector has a maximum 4
length; 5" connector has maximum 7
• Oversized chimneys should be relined with appropriate listed relin-
ing systems.
• Clean out access may be required.
RELINING SYSTEMS
• Suitability and approval of relining materials should be determined.
• Condition, size, height, and termination of the chimney to be
relined must be determined.
• No substitution of components should be made.
• Joints and connectors should be made according to manufacturer's
instructions.
NOTICE: Consult the authority having jurisdiction in
your area regarding listed chimney liner venting ap-
plications.
WARNING: Operation of improperly installed and
maintained venting system could result in serious
injury, property damage, or loss of life.
127116-01A
VENTING INSTALLATION Continued
/2 feet in length for every inch of
1
/2 foot
1
/2 foot length).
1
www.Superiorfireplaces.US.com
Figure 12 - Straight Installation into Masonry Chimney
Figure 13 - Typical Straight Installation with Listed Chimney Liner
9