Round
Top
Storm Collar
Flashing
Firestop
Spacer
Enclosure
Wall
Gas Vent
Length
Support
Plate
Adjustable
Length
Figure 7 - Typical B-Vent Installation
127116-01A
VENTING INSTALLATION Continued
Roof
Support
25mm (1")
Clearance to
Combustible
Material
Keep Electrical
Wires and
Building
Insulation Away
from Gas Vent
and Out of the
Required Air
Space
25mm (1")
Clearance to
Combustibles
www.Superiorfireplaces.US.com
INSTALLATION OF LISTED B-1 VENT
WARNING: Installation should only be made by
qualified persons who are familiar with the safety
procedures required for the installation of the product,
who are equipped with the proper tools and testing
instruments, and who have achieved proper certifica-
tion of licensing. Installations made by unqualified
persons can result in the risk of injury or electrical
shock which can be serious or even fatal.
Figures 8 through 10 show other options for the gas vent. When
venting through a side wall your vent pipe must have the proper
temperature rating (see Figure 10, page 8). Manufacturer's clearances
must also be maintained. Consult the authority having jurisdiction in
your area regarding venting through side wall.
Figure 8 - Vertical Venting Through Ceiling Using Two 90º
Elbows