Superior DXS3030TMN Installation And Operation Manual

Superior direct-vent gas stove installation and operation

Advertisement

Quick Links

P/N 900138-01 REV. NC 01/2014
Ce manuel d'installation est disponible
en francais, s implement en faire la de-
mande. Numéro de la pièce 900188-01.
WARNING
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
WARNING: If the information in these instructions is
not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
- Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR: Laissez cette notice avec l'appareil.
CONSOMMATEUR: Conservez cette notice pour consul-
tation ultérieure.
DIRECT-VENT
GAS STOVE
Portland
US
OTL Report No. 050-S-16b-5
P900138-00
AVERTISSEMENT

INSTALLATION AND OPERATION

MODEL
DXS3030TMN
This Gas Stove is factory equipped for 35,000 BTU input and can be converted to
25,000 using a smaller orifice (provided in optional orifice kit P/N H5966).
UNE SURFACE VITRÉE CHAUDE PEUT
CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
AVERTISSEMENT: Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire
au minimum le risque d'incindie ou d'explosion ou
pour éviter tout dommage matériel, toute blessure
ou la mort.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où vous
trouvez.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du fournis-
seur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par
le fournisseur de gaz.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DXS3030TMN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Superior DXS3030TMN

  • Page 1: Installation And Operation

    P/N 900138-01 REV. NC 01/2014 MODEL OTL Report No. 050-S-16b-5 Ce manuel d’installation est disponible DXS3030TMN en francais, s implement en faire la de- mande. Numéro de la pièce 900188-01. P900138-00 This Gas Stove is factory equipped for 35,000 BTU input and can be converted to 25,000 using a smaller orifice (provided in optional orifice kit P/N H5966).
  • Page 2: Table Of Contents

    CONGRATULATIONS! Horizontal Terminations ........16 Vertical Terminations ........16 When you purchased your new gas stove, you joined the ranks Horizontal Vent Termination Locations ....17 of thousands of individuals whose answer to their home heat- Gas Line Installation ..........18 ing needs reflects their concern for aesthetics, efficiency and our environment.
  • Page 3: Safety And Warning Information

    IMPORTANT SAFETY AND WARNING AVERTISSEMENT INFORMATION On ne devrait pas placer de vêtements ni d’autres matières inflammables sur l’appareil ni à proximité. WARNING WARNING Young children should be carefully supervised when they are in the same room as the appliance. Tod- Any safety screen or guard removed for servicing dlers, young children and others may be susceptible the appliance must be replaced prior to operating...
  • Page 4  T hese appliances are vented gas appliances. Do not burn wood  F OR YOUR SAFETY do not install or operate this appliance without or other material in these appliances. first reading and understanding this manual. Any installation or operation of the appliance deviating from that which is stated  T his appliance is only for use with the type of gas indicated on in this manual WILL void the warranty and may be hazardous.
  • Page 5: Homeowner - Attaching Safety In Operation Warnings

    ATTACHING SAFETY-IN-OPERATION WARNING LABELS ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIóN DE ADVERTENCIAS DE SEGURIDAD à LA SéCURITé D’UTILISATION EN OPERACIóN It is required that the safety instruction labels fur- nished with the fireplace be affixed to the operation Il est impératif que les étiquettes de sécurité...
  • Page 6: Orifice Size/Altitude Adjustment

    ORIFICE SIZE/ALTITUDE ADJUSTMENT THE GAS STOVE For altitudes above 2,000 feet (In Canada 4,500 FT/1370 M), the orifice • Must conform with all local, state and national installation codes. In should be de-rated by 4% for every 1,000 feet to maintain the proper the absence of local codes, the installation must conform with National ratio of gas to air.
  • Page 7: Codes And Approvals

    CODES AND APPROVALS COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS Certification (Massachusetts Approval #G3-0806-6) Gas appliances must be tested and certified by a nationally recognized These appliances are approved for installation in the US state of Mas- testing and certification laboratory to ANSI (American National Standard sachusetts if the following additional requirements are met: Institute) gas appliance safety standards.
  • Page 8: Pre-Installation

    Do not cut or remove the grounding prong from this plug. * Other approved chimney brand is Simpson Dura-Vent DV-GS. DXS3030TMN-35 DXS3030TMN-25 RATINGS NATURAL GAS...
  • Page 9: Preparing Your Stove For Installation

    Preparing Your Appliance For Installation Dimensions Read all instructions before beginning your installation. If instructions The gas line attaches to the gas valve at the back of the stove 2-1/2” in have not been read carefully, your installation could void your warranty from the left side of the stove and 8-1/2”...
  • Page 10: Clearances To Combustibles

    Alcove dimensions Clearances to Combustibles Minimum clearances to combustible materials in inches (millimeters): The minimum width between the alcove side walls is 51” 1295mm). The minimum height of the alcove is 46” (1168mm) and the maximum depth is 35” (889mm). Parallel Installation Alcove Dimensions 2”...
  • Page 11: Installation

    Conversion from Standard 35,000 BTU To Optional 25,000 BTU INSTALLATION Input To convert input from 35,000 BTUs to 25,000 BTU's, remove and replace Installing Door Trim And Spring Handle the stock burner orifice with the #36 NG orifice supplied in the optional orifice kit P/N H5924.
  • Page 12: Brick Panel, Log Set And Ember Installation

    Brick Panel And Log Set Installation 5. Place ember material (rockwool) over ports. The ember material can be placed to obscure air holes, but do not cover the air holes. If logs are not installed according to the log installation instruc- * Fifty percent or less of ember material (rockwool) supplied should tions, flame impingement and improper combustion could be used in LP installations.
  • Page 13: Vent Installation

    9. Set center log on support with charred surface toward you and rest Residential and Mobile Home Installations: against the rear log. These are the minimum pieces required. Other parts may be required for your particular installation. Minimum Components for Horizontal Installation: Horizontal Termination Kit which includes: •...
  • Page 14: Vent Parts List

    Vent Parts List Horizontal Vent Installation Secure Vent ® direct-vent pipe may be used with this appliance. Please see Venting terminals may not be recessed into a wall or siding. the lists below to verify the components available from each direct-vent pipe manufacturer.
  • Page 15: Vertical Vent Installation

    Flue Restrictors The flue restrictor settings shown in Figures 19 and 20 are for typical 14” Snorkel installations and may need to be adjusted from standard to take into account other variables in the installation to achieve proper combus- tion. See Flue Restrictor Guidelines on this page to assist you in making a proper flue restrictor adjustment.
  • Page 16: Horizontal Terminations

    Horizontal Terminations To install the stove with pipe directly out the back, a snorkel is not required for DXS3030TMN-25 gas stoves. A snorkel is required for the The shaded areas in the diagram below show all allowable combinations DXS3030TMN-35 gas stoves. See Pages 14 and 15 for snorkel instal- of vent configurations with horizontal terminations.
  • Page 17: Horizontal Vent Termination Locations

    Exterior Horizontal Vent Termination Clearance Requirements * See Item D in the Text Below. Center Line Exterior Wall Inside of Termination Corner Detail *18” Horizontal Termination 18” Ventilated Soffit Inside Corner = 9" in U.S. = 12" in Canada DETAIL D 3 ft.
  • Page 18: Gas Line Installation

    Gas Line Installation Fuel Inlet Pressure Manifold Pressure Type Desired Minimum Maximum On Hi On Lo This stove must be connected to the gas line in accordance with local Fire Fire codes and/or the National Fuel Gas Code, ANSI Z223.1 (In Canada, the current CAN/CGA B149.1 installation code).
  • Page 19: Installer - Attaching Safety In Operation Warnings

    INSTALLER INSTRUCTIONS - ATTACH SAFETY-IN-OPERATION WARNING LABELS It is required that the set of safety instruction labels that have been furnished with the fireplace be affixed to the operation and control points of the fireplace per the instructions on Page 5. It is the installers responsibility to ensure these warnings are properly affixed during installation.
  • Page 20: Operating Instructions

    Operating Instructions WHAT TO DO IF YOU SMELL GAS: • DO NOT try to light the appliance. Pre-Lighting Checklist • DO NOT touch any electric switch; do not use any phone in Be sure to check these items before the initial lighting of the your building.
  • Page 21: Flame Color And Behavior

    10. After pilot is lit, turn gas control knob counterclockwise Gas Control Knob Igniter to “ON.” Knob can only be turned to “ON” if the knob (pilot/on/off) has popped out. 11. To turn burner on, turn “ON/OFF” rocker switch to “ON” or set the thermostat to the desired temperature above room temperature.
  • Page 22: Air Shutter Adjustment

    Quiet Operation Proper Pilot Flame Appearance As the appliance is burning, a number of normal operational sounds may be heard. The flow of gas through the gas valve and orifice may make a rushing or whistling noise. If this noise is objectionable, it can be reduced by turning down the flame.
  • Page 23: Operating Options

    Operating Options Thermostat Wire Wire Size Maximum Length Your stove comes equipped with an “On/Off” rocker switch used to turn the burner on and off while the pilot light is on. The switch is a round 12 Gage 100 Feet rocker switch located behind the main control panel door.
  • Page 24: Maintenance And Servicing

    The viewing glass should be cleaned periodically (see Glass Door MAINTENANCE AND SERVICING Cleaning and Maintenance). Should repairs or maintenance of the stove require the disassem- WARNING bly of the vent/air intake system, the reassembly and resealing should be completed by a qualified service technician and follow Turn off gas and electrical power to the fireplace the instructions on Pages 13, 14 and 15 of this manual.
  • Page 25: Opening And Removing Door

    Opening and Removing Door Glass Door Swing the front door open to access the two 5/32” screws at the top of WARNING the glass frame and remove the two screws. To remove the door, grasp it firmly with both hands and lift it up. The glass door is fragile so it is •...
  • Page 26: Fuel Conversion

    Fuel Conversion Converting the stove between natural gas (NG) and propane (LP) can be accomplished by either changing the cassette (valve and pilot assembly) or installing a conversion kit (regulator, burner orifice and repositioning the slide orifice of the pilot). Only a qualified service technician should perform the conversion.
  • Page 27: Troubleshooting

    TROUBLESHOOTING NOTE: When troubleshooting the gas control system, be sure the external gas shut off valve, located at the gas supply inlet is in the “ON” position. IMPORTANT: Call your gas supplier or plumber for additional help with any gas control problem. Valve system troubleshooting should only be accomplished by a qualified service technician.
  • Page 28: Blower Wire Harness Diagram

    Wire Harness Diagram CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. ATTENTION: Au moment de l'entretien des commandes, étiquetez tous les fils avant de les débrancher. Des erreurs de cáblage peuvent entraîner un fonctionnement inadéquat et dangereux.
  • Page 29: Replacement Parts List

    REPLACEMENT PARTS - DXS3030TMN ACCESSORIES - DXS3030TMN Cat. No. Description Product Reference Information H3136 Cassette Assembly, NG (if LP, also requires 75265 Cat. No. Description Ship. Ship. conversion kit) Weight Volume H6034 Burner Assembly F1776 DXS3030TMN, Direct-Vent 189 lb. 24.06 cu. ft.
  • Page 30: Accessories

    ACCESSORIES - DXS3030TMN Cost Effective Solution • Simple On/Off operation • Works with millivolt and low voltage electronic ignition controls Flame and Heat modulation Kit includes: • Includes solenoid for SIT millivolt valves Remote and Receiver • Thermostatic, manual or up to 9 hour Count-...
  • Page 31: Stove Labels

    SAFETY / LISTING LABEL - DXS3030TMN MODEL SERIAL HOMOLOGUÉ FOYER RADIANT PRÉFABRIQUÉ AU VISION™ 35 MODÈLE GAZ -NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE Portland MANUFACTURED BY / FABRIQUÉ PAR: MAY BE INSTALLED IN RESIDENTIAL BEDROOMS AND MANUFACTURED (MOBILE) HOMES.
  • Page 32: Shutdown Procedure

    LIGHTING LABEL - DXS3030TMN FOR YOUR SAFETY READ BEFORE OPERATING POUR VOTRE SÉCURITÉ, LIRE AVANT L’ALLUMAGE WARNING: AVERTISSEMENT: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING SI VOUS NE RESPECTEZ PAS RIGOUREUSEMENT LES INSTRUCTIONS CI-DESSOUS, VOUS POURRIEZ ENCOURIR UN RISQUE D’INCENDIE ET/OU PROPERTY DAMAGE, INJURY OR LOSS OF LIFE.
  • Page 33: Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 34: Product Reference Information

    WARRANTY Normally, all parts should be ordered through your IHP distributor or dealer. Parts will be shipped at prevailing prices at time of order. Your gas appliance is covered by a limited warranty (provided with When ordering repair parts, always give the following information: appliance).

Table of Contents