Superior BXI2518MN Installation And Operation Instructions Manual page 13

B-vent gas stoves millivolt system
Table of Contents

Advertisement

Equipment
Shutoff Valve
Gas Valve
Figure 18 - Checking Gas Joints for Propane/LP Gas Burner
Gas Valve
Figure 19 - Checking Gas Joints for Natural Gas Burner System
PRESSURE TESTING BURNER SYSTEM GAS CONNECTIONS
1. Open equipment shutoff valve (see Figure 17, page 12).
2. Open propane/LP supply tank valve for propane/LP burner system
or main gas valve located on or near gas meter for natural gas
burner system.
3. Make sure control knob of burner system is in the OFF position.
4. Check all joints from equipment shutoff valve to thermostat gas
valve (see Figure 18 for propane/LP or Figure 19 for natural). Apply
commercial leak test solution to all gas joints. Bubbles forming
show a leak. Correct all leaks at once.
5. Light burner system (see Lighting Instructions, page 16). Check
all other internal joints for leaks.
6. Turn off burner system (see To Turn Off Gas to Appliance, page
17).
127116-01A
INSTALLATION Continued
Propane/
LP Supply
Tank
System
Equipment
Shutoff
Valve
Gas
Meter
www.Superiorfireplaces.US.com
INSTALLING OPTIONAL WALL MOUNT SWITCH - GWMS2
1. Connect one terminal of 25 ft. wire for the wall switch to the TPTH
terminal on the valve. Connect remaining wire terminal to the TH
terminal on the valve. Make sure that the wire terminals are in
the positions on the unit as pictured in Figure 20. If wires are not
connected as shown, the switch will not work.
2. Route the 25 ft. wire through openings provided on the sides of
the burner system to a convenient location to mount your switch.
3. Connect one bare wire end to each of the terminals of the GWMS2
wall switch.
4. Install the wall switch and cover in the wall.
Figure 20 - Control Valve Terminals
To Control
Switch or
Optional
Accessory
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bxi2518mp

Table of Contents