OBSERVED PROBLEM
Gas odor even when control knob is in
OFF position.
Gas odor during combustion.
Dark residue on logs or inside of burner
system.
BXI2518MN
• Rating: 30,000 Btu/Hr
• Gas Type: Natural Gas
• Manifold Pressure: 3.5" W.C.
• Minimum Inlet Supply Pressure: 5." W.C.
• Dimensions, (HxWxD):
27" x 21
/
" x 18" (68.6 x 54.6 x 45.7 cm)
1
2
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper
operation after servicing.
127116-01A
TROUBLESHOOTING Continued
POSSIBLE CAUSE
1. Gas leak. See Warning statement, page
22.
2. Control valve defective.
1. Gas leak. See Warning statement, page
22.
1. Improper log placement.
2. Air holes at burner inlet blocked.
3. Burner flame holes blocked.
4. Improper vent configuration

SPECIFICATIONS

BXI2518MP
• Rating: 28,000 Btu/Hr
• Gas Type: Propane/LP Gas
• Manifold Pressure: 10" W.C.
• Minimum Inlet Supply Pressure: 11" W.C.
• Dimensions, (HxWxD):
27" x 21

WIRING DIAGRAM

110/115
www.Superiorfireplaces.US.com
REMEDY
1. Locate and correct all leaks (see Checking
Gas Connections, page 12).
2. Replace control valve.
1. Locate and correct all leaks (see Checking
Gas Connections, page 12).
1. Properly locate logs (see Installing Logs,
Lava Rock, and Glowing Embers, page
15).
2. Clean out air holes at burner inlets. Peri-
odically repeat as needed.
3. Remove blockage or replace burner.
4. Follow venting configuration instructions
on pages 6 thru 10.
/