WARNING: Turn off burner system and let cool
before cleaning.
CAUTION: You must keep control areas, burners,
and circulating air passageways of stove with burner
system clean. Inspect these areas of stove and burner
system before each use. Have burner system inspected
yearly by a qualified service person. Burner system
may need more frequent cleaning due to excessive
lint from carpeting, bedding material, pet hair, etc.
GLASS DOOR
WARNING: Handle glass door panel with care.
Do not strike, slam or otherwise abuse glass. Do not
operate burner system with the glass door removed,
cracked, or broken.
WARNING: Do not use abrasive cleaners as this may
damage glass. Use a non-abrasive household glass
cleaner to clean glass. Do not clean glass when hot.
Glass must be cleaned periodically. During start-up it is normal for
condensation to form on the inside of the glass causing lint, dust,
and other airborne particles to cling to the glass surface. During initial
start-up a slight film may form on the glass due to paint curing. The
glass should be cleaned several times with a non-ammonia, non-
abrasive household cleaner and warm water after the first two weeks
of operation. Thereafter, clean the glass two or three times during each
heating season, depending on the usage and circumstances present.
Refer to Removing/Replacing Glass Door on page 14 of this manual
when removing glass door for cleaning.
WARNING: Only parts supplied by the manufacturer
should be used when replacing broken or damaged
glass door panel (see Replacement Parts, page 26).
This glass door panel is a complete unit. No substitute
materials may be used.
CAUTION: Wear gloves and safety glasses while
handling or removing broken glass. Do not remove if
glass is hot. Keep children and pets away from glass.
If glass has been broken, carefully remove glass door (see Removing/
Replacing Glass Door, page 14). Vacuum all glass pieces with a shop vac.
Use only the ceramic glass door replacement intended for this burner
system (see Replacement Parts, page 26 for details on ordering). No
substitutions may be made. See Removing/Replacing Glass Door,
page 14 for instructions for replacing glass door.
WARNING: Do not operate burner system with the
glass door removed, cracked, or broken.
127116-01A

CLEANING AND MAINTENANCE

PILOT AND BURNERS
• Remove ember material before cleaning burners and replace when
cleaning is complete.
• Burner and controls should be cleaned with compressed air to
remove dust, dirt, or lint.
• Use a vacuum cleaner or small, soft bristled brush to remove excess
dust, dirt, or lint.
LOGS
• If you remove logs for cleaning, refer to Installing Logs, Lava Rock,
and Glowing Embers, page 15, to properly replace logs.
• Use a vacuum cleaner to remove any carbon build-up on logs.
• Replace log(s) if broken. See Replacement Parts on page 26.
• Replace ember material periodically as needed. See Replace-
ment Parts on page 26.
VENTING SYSTEM
Conduct annual inspection of the venting system following these
guidelines:
1. Check areas of venting system that are exposed to the weather
for corrosion (rust spots or streaks and, in extreme cases, holes).
Have these items replaced immediately by a qualified service
person.
2. Remove the vent cap and shine a flashlight into the vent. Remove
any foreign material.
3. Check for evidence of excessive condensation. Continuous con-
densation can cause corrosion of caps, pipes, and fittings and can
be caused by having excessive lateral runs, too many elbows, or
exterior portions of the system being exposed to cold weather.
4. Inspect joints to verify that no pipe section or fitting has been
disturbed and loosened. Check mechanical supports such as wall
straps for rigidity.