Appendix B Event (Snmp Trap) Display When Using Serverview Operations Manager - Fujitsu ETERNUS DX60 S2 User Manual

Disk storage system
Hide thumbs Also See for ETERNUS DX60 S2:
Table of Contents

Advertisement

Appendix B Event (SNMP Trap) Display When Using
This appendix describes the display contents of events (SNMP Traps) that are notified to the
SNMP manager (monitoring server) when using the server management software "SeverView
Operation Manager" for monitoring the ETERNUS DX Disk storage system.
IMPORTANT
Alarm type
(--#TYPE)
Item fault
Item warning
Sensor status
changed
Maintenance
required
Information
event (*2)
Item fault to
normal (*2)
FUJITSU Storage ETERNUS DX60 S2 Disk storage system User's Guide -Operation-
ServerView Operations Manager
This appendix describes the display contents of events (SNMP Traps)
when using the MIB definition file for ServerView monitoring that is
downloaded from the ETERNUS DX Disk storage system.
For detailed information about ServerView Operations Manager, refer to
the ServerView Operations Manager manuals.
Display contents of the ServerView Operations Manager
Severity
(--#SEVERITY)
CRITICAL
Item fault event from %s, id: %x, message: %s
%s: fjdarySspMachineId
%x: fjdaryTrapItemId
%s: fjdaryTrapMessage
MAJOR
Item warning event from %s, id: %x[%x], message:
%s
%s: fjdarySspMachineId
%x: fjdaryTrapItemId
%x: fjdaryTrapWarningInfo
%s: fjdaryTrapMessage
CRITICAL
Sensor status changed event from %s, id: %x[%x],
message: %s
%s: fjdarySspMachineId
%x: fjdaryTrapItemId
%x: fjdaryTrapSensorInfo
%s: fjdaryTrapMessage
CRITICAL
Maintenance required event from %s, id: %x,
message: %s
%s: fjdarySspMachineId
%x: fjdaryTrapMaintenanceInfo
%s: fjdaryTrapMessage
INFORMATIONAL Information event from %s, message: %s
%s: fjdarySspMachineId
%s: fjdaryTrapMessage
INFORMATIONAL Item fault to normal, from %s, id: %x, message: %s 22
%s: fjdarySspMachineId
%x: fjdaryTrapItemId
%s: fjdaryTrapMessage
Copyright 2014 FUJITSU LIMITED
Details (--#SUMMARY)
variable-bindings (*1) for %s, %x
121
SNMP Trap type
specific
Meaning
trap No.
2
A component has
failed or degraded
5
A component
requiring
preventive
maintenance is
detected
6
Temperature error
is detected
7
An event requiring
maintenance or
preventive
maintenance is
detected
9
An information-
level event is
detected
An event notified by
"Item fault" returns
to normal status
P3AM-5512-07ENZ0