Appendix A Event Notification Message List
A.2 Message List
Event type
and event
M 21810xxx
M E005nxxx
M E10300xx
M E2070001
M E2070002
M E2070004
M E207000B
M E207000C
M E207000D
M E207000E
M E207000F
M E2070010
M E2070011
FUJITSU Storage ETERNUS DX60 S2 Disk storage system User's Guide -Operation-
SNMP Trap
Trap
Trap
Maintenance
code
No.
Info
7
21810xxx
RAID Group#0xxx recovered end of Rebuild processing
Rebuilding to a hot spare or a replaced disk is complete,
but Bad Data (data lost identifier) exists.
7
E005xxxx
WRITE BAD DATA
Writing of Bad Data (data lost identifier) occurs.
7
E10300xx
PINNED DATA was created CM#m
Pinned Data occurs.
7
E2070001
NOT READY(01:Configuration Error)
The device is in Not Ready status.
Shipment settings (model setting) and configurations are
not applied.
7
E2070002
NOT READY(02:CM F/W Version Error)
The device is in Not Ready status.
Firmware version for the CM is not correct.
7
E2070004
NOT READY(04:Restore Fail)
The device is in Not Ready status.
Backup is successfully complete, but cannot perform the
restoration.
7
E207000B
NOT READY(11:Power Off/Fail Incomplete)
The device is in Not Ready status.
Failed to power off. Or the device power turns off
immediately after the device powers on.
7
E207000C
NOT READY(12:Backup Fail)
The device is in Not Ready status.
Backup failed.
7
E207000D
NOT READY(13:Multi CM Down)
The device is in Not Ready status.
Adjoining CMs with LUs are degraded.
7
E207000E
NOT READY(14:Machine Down Recovery End)
The device is in Not Ready status.
Machine down recovery is performed.
7
E207000F
NOT READY(15:Machine Down Recovery Failed)
The device is in Not Ready status.
Failed to perform machine down recovery.
7
E2070010
NOT READY(16:DE Build Error)
The device is in Not Ready status.
Failed to configure DE because of miniSAS cable errors
or FC cable errors.
7
E2070011
NOT READY(17:CM Memory Shortage)
The device is in Not Ready status.
Memory capacities are smaller than the minimum value in
multiple CMs.
Copyright 2014 FUJITSU LIMITED
Upper: Message
Lower: Description
xxx: RAID group number
xxx: RAID group number
xx: CM module ID in which Pinned Data occurred
m: CM number in which Pinned Data occurred
103
Remarks
These messages
are notified when
"RAID Degradation
Event" is enabled
for Warning Level in
the event
notification setting.
They are not notified
during maintenance
operations.
These messages
are notified when
the relevant event
occurs.