2. Set the RS-485 parameters and click Save to save the settings.
By default, the Baud Rate is set as 9600 bps, the Data Bit is 8, the stop bit is 1 and
the Parity and Flow Control is None.
Note:
The Baud Rate, PTZ Protocol and PTZ Address parameters should be
exactly the same as the PTZ camera parameters.
12.10

Service Settings

Go to Configuration> Advanced Configuration> System > Service to enter the
service settings interface.
Service settings refer to the hardware service the camera supports, and it varies
according to the different cameras.
For the cameras support IR LED, ABF (Auto Back Focus), Auto Defog, or Status
LED, you can go to the hardware service, and select to enable or disable the
corresponding service according to the actual demands.
User Manual of Network Camera
Figure 12-18 RS-485 Settings