Table 56 Description of PWR LEDs with numbers
LEDs
OK
On
Off
Off
Fan LEDs (FAN)
The SRPU provides two fan LEDs—OK and FAIL—to indicate the working status of the fan tray.
Table 57 Fan LED description
LEDs
OK
On
Off
Off
Card LEDs (SLOT)
The SRPU provides card LEDs (SLOT).
The LSQ1MPUA0 SRPU provides numbered LEDs to indicate the status of LPUs in the corresponding
slots. The SRPU LED indicates the working status of the SRPU itself.
Other SRPU models provide LEDs without numbers to indicate the status of active SRPUs, standby
SRPUs, and LPUs.
NOTE:
The number of a slot on the S7506-V is marked on both left and right sides of the slot, and that on other
models is marked on the right side of the slot.
Table 58 Card LED description
LEDs
RUN
Blinking
Off
Off
On
On
Description
FAIL
Off
The corresponding power module is working properly.
The corresponding power module has no output power. (The cause can
On
be: the power module is faulty or not switched on; a power cable
connection problem occurs; the external power supply is unavailable.)
Off
No power module is installed in the corresponding slot.
Description
FAIL
Off
The fan tray is working properly.
On
A fan problem occurs or the fan tray is not in position.
Off
The switch is not powered on.
Table 58
Description
ALM
Off
The card is working properly.
On
The corresponding card is faulty.
This status occurs in the following cases:
The corresponding card is not in position.
Off
The card is not started (the software version of the switch does not match
that of the card).
On
The corresponding LPU is starting up.
Off
The corresponding SRPU is starting up.
shows the LED description.