Option
How to view
Press the System Options icon to access the
following system options:
RF jam detect
Demo mode
HW1 function
24 hour clock
Press the Siren Options icon to turn on/off the
following options:
Panel piezo beeps
Panel voice
Panel piezo alarm
Trouble beeps
Voice chime
HW siren supervision
Silent police panic
Alarm report verify
Press the Audio Verification icon to access the
following audio verification options:
Audio mode
Fire shutdown
Fire enabled AVM
Panic talk
VOX receiver gain
VOX microphone gain
VOX microphone gain range
Manual microphone gain
Press the System Tests icon to perform a sensor
test, communication test, or system download
test.
Displays the system's firmware version, touch
Version
screen version, and copyright information.
Access Programming screen
1.
From the Status & Settings screen, press the down arrow
to scroll to the Programming option.
2.
Press Enter.
3.
Enter the dealer or installer code (see Table 4 below) and
press OK.
Note: You have four seconds between number presses to
enter the code or you will be returned to the home screen.
Note:
Do not remove the panel power within 30 seconds of
exiting program mode.
Table 4: Simon® XTi programming codes
Code
Description
Dealer
You can use the dealer code to program all system
code
functions, including high-security options that are not
accessible with the installer code if it is different from the
dealer code. Depending on how the access code is set, the
default dealer access code is 654321, 54321, 4321 (factory
default), or 321. This code can be used for all programming.
Simon® XTi Installation Guide
Code
Description
Installer
Depending on how the access code is set, the default
code
installer code is 654321, 54321, 4321 (factory default), or
321. This code is limited to changing all but the following:
Dealer code, code length, downloader code, phone lock,
phone #1, phone #2, phone 1 report mode, phone 2 report
mode, HW1 function.
Access codes
Table 5 below describes the Access code menu programming
options.
Table 5: Access codes
Function
Default
Description
Dealer
4321
You can use the dealer code to program all
code
system options, including high-security
options that are not accessible with the
installer code if it is different from the dealer
code. Changing the dealer code to differ from
the installer code will prevent the installer
from viewing certain fields.
If you change the dealer code and enter
program mode with the installer code, the
installer will no longer be able to see the
following: code length, downloader code,
phone lock, phone #1, phone #2, phone 1
report mode, phone 2 report mode, HW1
function.
Installer
4321
You can use the installer code to program
code
most installer options, except for high-security
dealer options.
Master
1234
You can use the master code to arm/disarm
code
the system and to enter user programming
and bypass sensors.
User
Blank
You can use the user codes to arm/disarm the
codes 1
system.
to 8
Duress
Blank
You can use the duress code in place of the
code
master or user code to cause a silent alarm.
Code
Four digits Codes can be three to six digits long.
length

Sensors

These instructions describe how to add (learn) sensors,
touchpads, and other system devices into panel memory. The
panel recognizes a sensor when you press a sensor program
icon, press and release a tamper switch, press a sensor test
button, or put a sensor into alarm. Table 6 on page 8 describes
the programming method for each device.
Note:
If you are installing a sensor on a gun case, jewelry box,
or a similar case, and the sensor is active in level one, you
must direct bypass the sensor to avoid putting the panel into
alarm when the sensor and the magnet are separated.