Jungheinrich DFG 660 Operating Instructions Manual page 97

Hide thumbs Also See for DFG 660:
Table of Contents

Advertisement

6.2.2 Starting procedure for the TFG
DANGER!
Risk of escaping liquid gas if the truck does not start
Note the safety regulations governing the handling of liquid gas
((see "Safety regulations for handling diesel fuel and LPG" on page 45))
Close the gas bottle shut-off valve.
Set the key switch to "O"
Notify your superior.
Procedure
• Slowly open the shut-off valve on the LPG
bottles.
• Insert the key in the key switch (68) and
turn it to the "2" position.
• All the indicators light up briefly to test
operation.
Z
All the indicators except for the engine oil
pressure display, parking brake indicator,
indicator lamp for neutral position and
charge current indicator (163) should go
out after a short while. If not, stop the start-
up process and rectify the fault.
• Select LPG bottle 1 or 2. To do this move
switch (54) for LPG bottle 1 to the centre
position and for LPG bottle 2 to the lowest
position.
Z
In the highest position of the switch both
LPG bottles are disabled.
• Turn the key to position "3".
Z
Only apply the starter for a maximum of 15
seconds without interruption. The truck is
equipped with an immobiliser which
prevents it from starting again while the engine is running.
• Release the key as soon as the engine
starts. The key automatically reverts to the
"2" position.
Z
All indicators lights except for neutral
position and parking brake should go out
as soon as the engine starts. If not, stop
the engine immediately and rectify the
fault.
Truck ready for operation.
98
S12
S13
S15
S7
S8
S24
X28
S20
S26
S30
S20
S26
S30
163
68
3
S4
S5
S6
XR9
54
68

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents