6.3.3 Raising the Cab Electrically ( o)
DANGER!
Before tilting the cab, allow the motor
and muffler to cool off. Unlock the
muffler and tilt it back.
Procedure
• To do this release the lever (212) and
unlock the button (211). The exhaust
purifier can be carefully turned back as
far as the stop.
CAUTION!
Before activating the lift pump always close the lowering valve.
• To close, insert the long side of the pump rod through the infeed (214) onto the
hexagon of the lowering valve and turn clockwise as far as the stop.
Lifting
Procedure
• Press switch (217) on the service panel.
The cab is tilted back electrically until the
cab locking device (188) engages.
• After the locking device (188) engages, it
must also be secured in place with the
lever (216).
6.3.4 Lowering the Cab
see section (see "Lowering the Cab" on
page 165).
DANGER!
No persons are permitted in the area
around the cab while it is being lowered.