During travel
Procedure
• Be aware of the "High counter pressure"
display light. The light may flash with high
motor speeds and heavy loads.
• If the display light flashes continuously at a
high motor speed, the filter must be
regenerated as quickly as possible.
• If the filter system is working normally and
the
regeneration
observed, the display light will not light up
during operation.
Regeneration
Z
The filter must be regenerated daily, or at the latest after 8 operating hours (sooner
if the engine is used less frequently).
CAUTION!
The regeneration process must not be interrupted!
Procedure
• Connect the electrical wires and air hose to the truck (standard system only).
• Switch the control device on.
• Check with the ammeters whether the system is working, All three instruments must
show an amplitude simultaneously. The regeneration is complete after 40 minutes.
The ammeters show 0 amps and the green lamp is lit.
• Switch off the control device.
• Disconnect the electrical wires and air hose from the truck (standard system only).