Remove the LPG bottle
CAUTION!
The connection has a left thread
Procedure
• The LPG bottle console is released with
the finger screw (50).
• Unfold the console (51) as far as the stop.
• Unscrew the union nut (53).
• Remove the hose (45) and immediately
screw the valve cap onto the empty LPG
bottle.
• Loosen the toggle-type fastener with the
handle (52).
• Carefully remove the LPG bottle from the
bracket and place it down securely.
Inserting a new LPG bottle
Procedure
• Insert the LPG bottle into the bracket
• Align the hose connection downwards.
• Clamp the toggle-type fastener with the
handle (52).
• Unscrew the valve cap.
• Fit the hose (45) in accordance with
instructions.
• Carefully open the shut-off valve (49).
• Check the hose connection for leaks using
a foam-forming agent.
The replacement is now complete.