2. Flange Back Adjustment

(Using the minipattern box)

The inner focus lens flange back adjustment is carried out auto-
matically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Siemens star chart with ND filter for
Subject
the minipattern box (Note 1)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
4E to 5D, 61
Note 1: Dark Siemens star chart.
Note 2: Perform this adjustment after performing "HALL
adjustment".
Switch setting:
1) NIGHT SHOT .................................................................. OFF
2) DIGITAL ZOOM (Menu display) ................................... OFF
3) STEADY SHOT (Menu display) .................................... OFF
Preparation for adjustment
The minipattern box is installed as shown in the following figure.
Note: The attachment lenses are not used.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjust the power supply
output voltage to the specified voltage written
on the sheet which is supplied with the
minipattern box.
Minipattern box
Regulated power supply
Output voltage : Specified voltage ±0.01 Vdc
Output current : more than 3.5 A
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Need not connected
Black (GND)
Fig. 5-1-6
Below 3 cm
Camcorder
Camera
table
5-16
Adjusting method:
1) Install the minipattern box so that the distance between it and
the front of the lens of the camcorder is less than 3 cm.
2) Make the height of the minipattern box and the camcorder
equal.
3) Check that the output voltage of the regulated power supply is
the specified voltage ± 0.01 Vdc.
4) Check that at both the zoom lens TELE end and WIDE end,
the center of the Siemens star chart and center of the exposure
screen coincide.
5) Select page: 0, address: 01, and set data: 01.
6) Select page: 6, address: 82, and set data: 01.
7) Check that the data of page: F, address: 4E to 5D and 61 is the
initial value (See table below).
Address
Data
4E
2E
4F
12
50
48
51
F1
52
18
53
5D
54
66
55
00
56
19
8) Select page: 6, address: 02, and check that the data is "00".
9) Select page: 6, address: 01, set data: 13, and press the PAUSE
button of the adjustment remote commander.
10) Select page: 6, address: 01, set data: 27, and press the PAUSE
button.
(The adjustment data will be automatically input to page: F,
addresses: 4E to 5D and 61)
11) Select page: 6, address: 02, and check that the data is "01".
Processing after Completing Adjustments
1) Turn OFF the main power supply (8.4 V).
2) Perform "Flange Back Check".
Address
Data
57
00
58
19
59
00
5A
00
5B
04
5C
00
5D
00
61
00