3—F-Series Camera Configuration
3.3.5

Digital Video Configuration

Note
When defining the ports for digital video, streams are setup sequentially; 0, 1, 2, and 3. If a
stream is enabled, the server will use the RTP/RTSP over HTTP port parameter to define the
port number (if left blank, 8080 is used). A subsequent stream's configuration takes
precedence so the same port needs to be defined for all enabled video streams. (But actually
you could really only define a non-default port for the last video stream configured.)
Step 1
Click Video IR. The screen at the right
will be displayed.
Step 2
Enter the parameters for your IR video
stream.
The IR Stream Name contains the
connection string for the IP video. The
default value recognized by FSM as
ch0 is:
rtsp://192.168.250.116/ch0.
Enter the appropriate IP video
connection string for your installation.
3.3.6

Configuring Network Remote / VMS

Several types of third-party Video
Management System (VMS)
systems are supported by the
camera. To configure the camera to
operate with a VMS Interface,
select the Network Remote / VMS
link on the left side of the page. By
default no VMS Interface is
configured; use the pulldown to
select the appropriate type of VMS
and click the Add button.
The New Device Creation screen will
appear. Set the communication
parameters to match the remote
system and click on the Create
button.
After the device is created, click on
the Save button to save the
configuration, and then restart the
server.