Recall Stored Label Format - Datamax E-Class Mark II Programmer's Manual

Class series ii
Hide thumbs Also See for E-Class Mark II:
Table of Contents

Advertisement

r

Recall Stored Label Format

This command is used to retrieve label formats stored on a memory module. Embedding
recalled labels, up to 6 levels of nesting, within a recall label is also possible.
Syntax:
Where:
Class Series 2 Programmer's Manual
Label Formatting Command Functions
rnn...n
- Is a label name, up to 16 characters in length.
nn...n
The samples below explain different ways to recall and print a label
format. (Use <STX>W to view a memory module's directory.)
String Sent:
Sample 1:
<STX>L<CR>
rTEST<CR>
Q0002<CR>
E<CR>
Sample 2:
<STX>L<CR>
rTEST<CR>
X<CR>
<STX>G<CR>
Sample 3:
<STX>L<CR>
D11<CR>
PO<CR>
SO<CR>
rTEST<CR>
E<CR>
The sample below explains recall embedding.
String Sent:
Sample:
<STX>L
rLABEL1
191111111111LABEL1FIELD1
sGLabel1
<STX>L
rLABEL1
191111111111LABEL2FIELD1
sGLabel2
<STX>L
rLabel2
19111111111LABEL3FIELD1
E
Printer Interpretation:
Begin label format
Retrieve format named TEST
Quantity requested = 2
Terminate formatting and print
Begin label format
Retrieve format named test
Terminate formatting
Print
Begin label format
Dot size = 1x1
Print speed O
Feed speed O
Retrieve format named test
Terminate formatting and print
Printer Interpretation:
Store label 1
Store label 2
Print label 3
What gets printed:
LABEL1 FIELD1
LABEL2 FIELD1
LABEL3 FIELD1