Stx W Test Flash Memory Module; Stx X Set Default Module; Stx X - Datamax E-Class Mark II Programmer's Manual

Class series ii
Hide thumbs Also See for E-Class Mark II:
Table of Contents

Advertisement

STX w
Test Flash Memory Module
This command tests the Flash module. The time for each test will vary from 20 to 120
seconds, depending upon the size of the module. All stored data will be destroyed. If
no module is present, there will be no printer response.
Syntax:
Where:
Response format:
Where:

STX X

Set Default Module
This command, typically used prior to the loading of PCL-4 bitmapped fonts (see Font
Loading Commands), is designed to allow the user to select between modules when
downloading information. The default module is one of the following:
1. The first alpha designator of the existing modules if item 2 has not occurred.
2. The module selected by this command.
Syntax:
Where:
Sample:
Class Series 2 Programmer's Manual
System-Level Command Functions
<STX>wa
- Module designator; see Appendix K.
a
Module A: xxxxK results
- Module tested.
A
- Module size in Kbytes.
xxxx
results
- Test results given as "Good" or "Bad".
<STX>Xa
- Module designator; See Appendix K.
a
<STX>XB
The sample above sets "B" as the default module.