Extended System-Level Command Functions
(RL) Ribbon Low Diameter – This command sets the threshold for a low ribbon
indication, where nnnn is the diameter in hundredths of inches.
(RM) Rewinder Equipped – This command allows the printer to sense the powered
internal rewind option. A (or Y) - automatically senses device presence; if
undetected, no error is generated. E - enables the device, where its presence must
be detected; otherwise, a fault is generated. N or D - disables device detection.
(RO) Row Offset – See Rnnnn (in Label Formatting Command Functions) for
command details.
(RP) Ribbon Low Pause – This command (when enabled) pauses the printer when
a Ribbon Low Diameter warning is declared; the PAUSE Button must be pressed to
continue printing.
(RR) Rewinder Adjust – This command changes the torque applied by the
powered rewinder, in percentage points of the nominal force, to minimize TOF
registration drift (sometimes evident when using small or narrow media).
(RS) Ribbon Low Signal – This command sets the signal output type for the
Ribbon Low Diameter condition when using the optional GPIO (see Appendix J).
(RV) Reflective Paper Value – This command sets the threshold value for the
reflective media sensor's paper parameter.
(RW) Retract Delay – This command sets a time delay for the retraction of a
presented label, where the time specified is multiplied by ten milliseconds.