Pim Action Table - HP 743 Service Handbook

9000 series 700
Hide thumbs Also See for 743:
Table of Contents

Advertisement

To identify the failed FRU(s) after an HPMC, follow these steps:
1
Examine the "Other Processor Data" words returned from the PIM command
to display the latest error information from the last TOC, LPMC, or HPMC interruption
detected.
2
Compare the values from the PIM command with those shown in Table 4-4 and take
the appropriate action.
Check
Type Word
0x80000000
0x40000000
0x20000000
N/A
0x20000000
N/A
0x20000000
N/A
0x20000000
N/A
0x20000000
N/A
0x20000000
N/A
Dealing with HPMC (Uncorrectable Error)
Table 4-4 PIM Action Table
Cache
Bus Check
Check
Word
Word
N/A
0x00210003
0x00310007
0x00310007
0x00310007
0x00310007
0x00310007
System
Responder
Word
N/A
Replace CPU board
0x00000000
Refer to Determin-
0xEFFFFFF
ing the Faulty
Memory Card, later
in this chapter.
0xF0000000
Replace CPU
0xF01FFFFF
board.
0xF0200000
Replace EISA tray,
0xF0207FFF
if present, or
replace CPU board.
0xF0280000
Replace PCMCIA
0xF029FFFF
adapter. If problem
persists replace
CPU board.
0xF0300000
Replace CPU
0xF031FFFF
board.
0xF0400000
Check VME system
0xF3FFFFFF
configuration and/
or replace CPU
board.
Troubleshooting
Action
4-19