Configuration
System Configuration Menu
5
Typing 2 Enter at the SYSTEM CONFIGURATION MENU puts the following BPR
submenu on the screen:
Current BPR configuration:
VME address
AM code
values example: 0x12345678 0x0d
Type value(s), then press [Enter/Return]
The general sequence of operations in this menu is:
6
Type in the data (VME address, AM Code) as one line, as indicated by the "value ex-
ample" listed below the "AM code" line.
7
Press Enter to exit this menu.
There are 2 data values for BPR, separated by spaces. Values not entered are ignored. Val-
ues entered or shown with a 0x prefix are hex numbers; otherwise they are decimal.
An arbitrary number of commands may be added to the debug environment. You can also
add items to the firmware, hardware, and system configuration menus.
3-28
= 0x00000000
= 0x00