Choose the right power cable for the system
You should choose the correct size (gauge) of cable
depending on usage of power and cable distance as
indicated below for your reference.
Recommended Cable Size by Power and Distance
(DC12V system)
Total RMS
Power
3m
5m
(Watts)
96.84ft
16.40ft
5.3mm
5.3mm
2
100W
10 gauge
10 gauge
5.3mm
8.4mm
2
200W
10 gauge
8 gauge
8.4mm
2
13.3mm
300W
8 gauge
6 gauge
13.3mm
21.2mm
2
500W
6 gauge
4 gauge
American Wire Gauge (AWG):
Wire Size
AWG gauge
mm
2
0000
0000
107.22
107.22
000
85.01
00
67.43
0
53.49
1
42.41
2
33.62
3
26.67
4
21.15
5
16.77
6
13.30
7
10.55
8
8.37
9
6.63
10
5.26
11
4.17
12
3.31
13
2.63
14
2.08
Choose the right controller for the system
• Rated Solar Current should be more than Rated
Power of Solar Panel.
• Rated Load Current should be sufficient to cover
overall load current.
Choose right Inverter for the system
• Make sure input voltage and out put voltage for the
system.
• Rated Load Current should be sufficient to cover
overall load current.
Solar Powered Repeater System
Distance
10m
20m
32.81ft
65.62ft
98.43ft
8.4mm
13.3mm
21.2mm
2
2
2
8 gauge
6 gauge
4 gauge
13.3mm
21.2mm
33.6mm
2
2
2
6 gauge
4 gauge
2 gauge
2
21.2mm
2
33.6mm
2
53.5mm
4 gauge
2 gauge
0 gauge
33.6mm
53.5mm
67.4mm
2
2
2
2 gauge
0 gauge
00 gauge
Ohms
Ohms
per 1000 ft
per km
0.0490
0.0490
0.1607
0.1607
0.0618
0.2027
0.0779
0.2555
0.0983
0.3224
0.1239
0.4064
0.1563
0.5127
0.1970
0.6462
0.2485
0.8151
0.3133
1.0276
0.3951
1.2959
0.4982
1.6341
0.6282
2.0605
0.7921
2.5981
0.9989
3.2764
1.2600
4.1328
1.5880
5.2086
2.0030
6.5698
2.5250
8.2820
30m
2
2
2
2
65
Need help?
Do you have a question about the IC-FR3000 Series and is the answer not in the manual?
Questions and answers