Limit Switch Setup
STEP 8
Loosen the screws on the limit switch cams
and position the cams to the desired
locations. There are additional holes
provided in case of a wide or tight angle of
opening or closing.
Move the gate manually and ensure that the
limit switch gets actuated at the desired
open and closed position. The limit switch
will click when engaged by the limit cam.
Retighten the screws on the limit switch holders
once the proper position has been determined.
CAUTION – DO NOT OVERTIGHTEN SCREWS!
Note: Leave cover off until after the installation
of the control box and the electrical
installation. Verify that the operator opens
and closes to the desired position under
power. Make any adjustments as necessary.
STEP 9
Replace the cover and secure it with screws
provided after finishing final adjustments.