Audible Alarm Reset Switch Installation

Reset for the Audible Alarm
UL325 standard requires an audible alarm to go off after two consecutive events
detected by the primary entrapment protection of the gate operator (obstruction sensor).
The audible alarm will continue to sound for 5 minutes or until a stop command
gets actuated.
The Stop command can be actuated in two different forms
1. Using the built in stop switch in the control board or
2. Using an external stop button within the sight of the gate, away from moving
parts of the gate and out of reach of children.
Manual Stop

Warning Placard Installation

All warning signs and placards must be installed where
visible in the area of the gate. A minimum of two
placards shall be installed. A placard is to be installed
in the area of each side of the gate and be visible.