GATE OPERATOR INSTALLATION
GATE OPERATOR INSTALLATION

Opening/Closing Setup:

To have the gate operator slow down prior to reaching its limits use the following steps:
1. Setup the limit switches manually at the desired open and close position.
2. Allow the gate operator to run a full open and close cycle (from limit to limit)
without interruption.
Note: During the first full open and close cycle: The gate operator doesn't slow
down prior to reaching its limits. During subsequent cycles: The gate operator will
slow down prior to reaching its limits.
3. Verify that the gate opens and closes to the desired position.
To change the open or close limit position(s) the following steps MUST BE taken:
A. Reset the gate operator by performing one of the following steps:
i. Disconnect the power harness or
ii. Disconnect the motor harness or
iii.Actuate both limits at the same time
B. Repeat steps 1,2 and 3.
Reference Wiring Diagram
Connect the lead wires as shown
To Limit
Switches
Limit Switch Connections
The Limit Switches are wired as shown
TECHNICAL SUPPORT 1 800 908 0884
Wire Lead
From Control Box
To Motor
Slow
Fast
Slow
Note: Use this wiring
diagram as a guide to
connect the wires to the
motor unit.
Yellow
Brown
Orange
Red
15