INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FO R T H E V I K I N G H -1 0 GAT E O P E R ATO R U L 3 2 5 C L A S S I , C L A S S I I , C L A S S I I I , A N D C L A S S I V C O M P L I A N T Residential and Commercial Vehicular Slide Gate Operator...
Page 2
• Built-in motor heater for cold weather applications • NEW: Smart Position Sensor tracks the exact gate position during power outages and • Equipped for 115/230 VAC, 24 VAC/VDC and when the gate is moved manually Solar power supplies THE VIKING H-10™ SLIDE GATE OPERATOR...
A N D A W A Y F R OM T H E G A TE P AT H P E R I M E TE R . VIKING TECHNICAL SUPPORT 1.800.908.0884...
Page 5
F or E T L c o m p l i a nc e : T he fo ll o wi n g ca n a l s o b e u s e d - A SO : 2 5 . 3 0, 2 5 . 4 5 , 95 . 2 0 / / M i l l e r E d g e: M E1 1 0 VIKING TECHNICAL SUPPORT 1.800.908.0884...
• In particular, regular checks are recommended in order to verify that the safety devices are operating correctly. All installation, maintenance and repair work must be documented and made available to the user. VIKING TECHNICAL SUPPORT 1.800.908.0884...
CAUTION: To Reduce the Risk of Fire or Injury to Persons: a. Use only the following type and size battery(ies): Yuasa NP7-12 or VIKING DUBA12 b. Do not dispose of the battery(ies) in fire. The cells may explode. Check with local codes for possible disposal instructions.
Open Limit. Refer to page 18. STEP 1: STEP 2: Connect the monitored entrapment protection sensor(s) to the Viking Control Execute the Learn Process: Board. • Press and release the “Diagnose” button until you see...
Activation of the reset control shall not cause the operator to start. 3. Using the “Alarm Reset ” Button on the operator that is externally accessible from the covers Access Door. STOP RELEASE ENGAGE RESET External STOP Stop Button Minimum VIKING TECHNICAL SUPPORT 1.800.908.0884...
• A minimum of two placards shall be in- stalled. • A placard is to be installed in the area of each side of the gate and be visible. VIKING TECHNICAL SUPPORT 1.800.908.0884...
17. MODULAR POWER BOX disconnects batteries from the charging 12. MANUAL RELEASE/MOTOR SWITCH removable; provides a convenient solution circuit during troubleshooting discontinues power to the motor and for optional low voltage installations allows for manual operation of the gate VIKING TECHNICAL SUPPORT 1.800.908.0884...
Follow the local building code to determine the required depth of the concrete pad. 2. Pad measurements recommended by Viking Access Systems are at least 24” long, 18” wide and 24” deep to ensure the stable operation of the operator, and a minimum of 4” above level grade to avoid any flooding of the machinery.
Provide at least 12 ” separation between low and high voltage conduits. Gate 4" Minimum Top of Pipe 5¾" 7¾" 16" (Reference) 15⅞" with 2-½” IPS Pipe 3" O.D. Pipe (2⅞” OD) Grade Level (Maximum) Consult Local Codes for Depth and Concrete Requirements VIKING TECHNICAL SUPPORT 1.800.908.0884...
Gate Operator Track Concrete Pad See Detail Below Concrete Pad Gate Operator Track Concrete Pad Concrete Pad Gate Route Chain As Shown Safety Guard Not Supplied by Viking Access Systems Fixed Pulley Gate Operator Concrete Pad VIKING TECHNICAL SUPPORT 1.800.908.0884...
Page 17
Adjust the Chain to provide 6”-8” of slack measured from the imaginary taut line, straight down to the lowest point of the chain as illustrated below. 14⅜" Chain Catenary 6"- 8" VIKING TECHNICAL SUPPORT 1.800.908.0884...
• All ground wires must be as short and as thick as possible. • Always use a single bonding point for grounding. • Connect the Earth Ground and Power Ground wires together. • Prevent unnecessary turns or loops in all ground wires. VIKING TECHNICAL SUPPORT 1.800.908.0884...
The number of cycles achieved daily is dependent on many factors, including local solar radiation data and power consumption of the motor and accessories. It is very important that you consider this when using solar power. VIKING TECHNICAL SUPPORT 1.800.908.0884...
“Re-Open” LED be illuminated. This alone is inconsequential. will be illuminated. This alone is inconsequential. TECHNICAL TIP: For more information regarding accessory connections to the Control Board and individual input terminal functions, refer to pages 26-27. VIKING TECHNICAL SUPPORT 1.800.908.0884...
2. Repeat STEP 2 above to set the limit. LIMIT LED INDICATIONS Gate is not at the set limit position. SOLID Gate is at the set limit position. FLASHING Limit position is not set or has been erased. VIKING TECHNICAL SUPPORT 1.800.908.0884...
• Toggle the “Diagnose” button until you see DUAL MODE on the LCD Display. • Default setting is OFF. • Press and hold the “Stop” button. • Toggle the “Diagnose” button once. • The feature should now be displayed as ON. VIKING TECHNICAL SUPPORT 1.800.908.0884...
PRIMARY/SECONDARY SETUP Wireless Communication Options REQUIRED ADD-ON: Viking Konnect - Wireless Primary/Secondary Kit PART# VA-KONNECT-MS ! Technical Tip: DO NOT set the “Timer” and/or “Overlap” features on both operators Control Boards. Only turn these features on at the Primary Control Board.
Automatically closes the gate after This Feature is disabled on Slide Gate the selected amount of time from 1-60 models. seconds. Turning the dial between “0” and “OFF” will disable this feature, requiring a close command to close the gate. VIKING TECHNICAL SUPPORT 1.800.908.0884...
By inserting the wire-jumper plug into Barrier Arm Operators. Activating the “Fail Safe/Secure” connector: this feature allows for synchronized The gate will require more effort to operation with Barrier Arm Operators. manual move. See page 33. “EXT” Available for future developments. VIKING TECHNICAL SUPPORT 1.800.908.0884...
“Alarm Reset” switch has been when it has been triggered. actuated. (refer to page 8) A. Solid: Obstruction. Detected a sudden or abrupt increase in gate resistance. B. Flashing: Overload. Detected a more subtle, but sustained increase in gate resistance. VIKING TECHNICAL SUPPORT 1.800.908.0884...
1. Use the “Diagnose” button to scroll through the LCD menu to “LOCK MOD” 2. Press and hold the “Stop” button on the Control Board. 3. Press and release the “Diagnose” button to turn this feature ON and OFF. VIKING TECHNICAL SUPPORT 1.800.908.0884...
Each input Terminal (i.e. Radio, Exit, Re-Open, UL) has a corresponding Status LED that when illuminated indicates an input is currently being provided to the terminal and the gate is responding accordingly. (See pages 34-35 LED References) VIKING TECHNICAL SUPPORT 1.800.908.0884...
Page 29
ACCESSORY CONNECTIONS Relays In General NOTE: Viking Access Systems does not provide the external safety devices and access controls. These items can be purchases from your dealer or distributor. In General Glossary of Terms 1. Terminal: Wire Connections. In regards to the Viking Control Board, 2.
By having the radio receiver connected as illustrated and with the “Timer” OFF: This type of configuration is not recommended for commercial installations. 2. Open Only By having the radio receiver connected as illustrated and with the “Timer” ON. VIKING TECHNICAL SUPPORT 1.800.908.0884...
ACCESSORY CONNECTIONS Photocell NOTE: The operator may be equipped with a FA-XP30-10K Photocell. Refer to pages 6-7 for UL325 requirements. UL or Re-Open – COM and VIKING TECHNICAL SUPPORT 1.800.908.0884...
Loop 6 Twists/Foot Viking Loop Rack Loop Until Its Connection to the Loop Rack Open Center Re-Open Exit Center Loop Exit Center Center Re-Open Inside Re-Open Re-Open Loop Exit Loop Control Board Connector Loop Sensor Connector VIKING TECHNICAL SUPPORT 1.800.908.0884...
50-100 Continuously Wind Wire in Loop Slot for the Required Number of Loops Dimension “A” = 5’ for Single Gate 6’ for Dual Gate Outside Inside Exit Reopen Reopen Loop Loop Loop Gates in Closed Position VIKING TECHNICAL SUPPORT 1.800.908.0884...
The control boards “Magnetic Lock ” relay is rated for 10A-250VAC . TECHNICAL TIP: The Magnetic Lock Relay LED will indicate status of the on-board relay even if a lock is not connected to the Control Board. Refer to page 34. VIKING TECHNICAL SUPPORT 1.800.908.0884...
1. Open Command is provided only to the Barrier Arm operator. 2. The Barrier Arm will send an open input to the Viking gate operator; Barrier Arm will delay to open until the Viking gate operator reaches its Open Limit.
Re-Open terminal or when more than one device is connected (pg 6-7, 18, 26, 30). “ATG” Normal Condition. SOLID Control Board is receiving an input from a device connected to the ATG 9, 10 terminal (pg 26). VIKING TECHNICAL SUPPORT 1.800.908.0884...
Page 37
“AC VOLTAGE OUTPUT” There is no output voltage from the Power Supply Panel Assembly. 23 “AC POWER” SOLID Normal Condition for High Voltage installations. High Voltage is not supplied to the Modular Power Box (pg 16). VIKING TECHNICAL SUPPORT 1.800.908.0884...
Gate is at the limit open position and timing to close - The display shows the actual time left before closing __ SEC Indicates the number of connected Monitored Entrapment Protection Sensors UL LEARN NO LEARN that are being monitored. = no sensors learned. (pg 6-7, 18) UL_ RO_ VIKING TECHNICAL SUPPORT 1.800.908.0884...
Page 39
The Integrated Heater has been enabled to turn on at the open and/or close ___ ON “CLS” “ACTV” limits (pg 27) will also be displayed while it is heating. LOCK MOD The Lock Mode feature is turned (pg 25) VIKING TECHNICAL SUPPORT 1.800.908.0884...
Page 40
ERR REFV One, or more, of the Control Board internal reference voltages are incorrect. WRONG ERR SENS There is a problem with the required monitored sensor(s) connected to the “UL” and/or “Re-Open” input terminals (pg 6-7, 18). VIKING TECHNICAL SUPPORT 1.800.908.0884...
Page 41
The reference voltages to or from the SPS module is incorrect. WRONG The SPS module pickup sensor(s) are not reading properly. ERR SPS The Control Board does not see any data from the SPS Sensor. This will also prevent the Lock Mode feature from functioning. MISSING VIKING TECHNICAL SUPPORT 1.800.908.0884...
If within range, replace the SPS Sensor. 4.7VDC - 5.3VDC. If out of range, call Viking Technical Support to further troubleshoot. Check that the Motor is responding to commands. Check that the SPS sensor is properly connected and secured to the Gearbox.
No agreement to replace or repair shall constitute an admission by the Seller of any legal responsibility to effect such replacement to make such repair, or otherwise. VIKING TECHNICAL SUPPORT 1.800.908.0884...
Page 45
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to a particular Purchaser. This Limited Warranty gives the Purchaser specific legal rights. The Purchaser may also have other rights, which vary from state to state. VIKING TECHNICAL SUPPORT 1.800.908.0884...
Off-site access to operator diagnostics and perform firmware updates from just about anywhere with cellular service. With the Viking Monitor App, this tool allows you to monitor and label multiple operators by site and location for quick reference. Provides error notifications, operator status, settings and diagnostic information.
Page 47
OUR CONTINUOUS COMMITMENT TO EXCELLENCE Viking Access Systems is continuously working hard to identify and design products that will appeal to the industry and its needs. As technology continues to advance, we have developed a completely efficient and intelligent line of gate operators to meet the changing demands.