GATE OPERATOR INSTALLATION

Limits Setup

STEP 1
Instal the Positive Stop for the open limit
and adjust the open limit position.
! IMPORTANT:
Each of the Positive Stops are designed for a specific limit position.
The Positive Stop locations illustrated below are for Open Left swinging gates.
Swap the Positive Stop locations and rotate the Motor/Gear Assembly 180° for Open
Right swinging gates.
Open Left
STEP 3
Reengage the gate:
Close the Release Levers and manually move the gate until it reengages with the Release
Mechanism.
Lock the Release Levers by rotating the Release Key away from the gate post.
STEP 4
Learn the Limit positions:
Allow the gate operator to run a full open and close cycle (from stop to stop) without
interruption so that the operator will learn when to slow down before reaching the limits,
providing controlled operation.
1 6
STEP 2
Instal the Positive Stop for the close limit
and adjust the close limit position.
VIKING TECHNICAL SUPPORT 1.800.908.0884