Table of Contents

Advertisement

! NOTE:
1. The 1st cycle after the limit setup is the "Learn Cycle". Allow at least one complete
cycle to confirm your settings.
2. During the limit setup process, the operator will run at half speed.
STEP 1
Connect the "Motor Harness" to the Control
Board.
a. "OPEN RIGHT" Connector if the gate opens
to the Right, when viewed from inside.
b. "OPEN LEFT" Connector if the gate opens
to the Left, when viewed from inside.
STEP 2
Position the gate to one of the desired
limit positions then press and hold the
corresponding Limit Button until the LED
stops flashing and illuminates solid.
Repeat this step for the other limit position.
Tip:
The gate can be moved electronically with the "Open", "Stop" and "Close" buttons
on the Control Board or manually by following the instructions on page 7.
To Readjust Limits:
1.
Clear the current limit setting by holding down the corresponding Limit Button until
the LED is flashing.
2. Repeat STEP 2 above to set the limit.
OFF
Gate is not at the set limit position.
SOLID
Gate is at the set limit position.
FLASHING
Limit position is not set or has been erased.
VIKING TECHNICAL SUPPORT 1.800.908.0884
LIMIT LED INDICATIONS

LIMITS SETUP

1
2
1 9