6. Other
6.4
Option Counter
6.4.1
Removal of the Mechanical Counter (Option for bizhub 160/161/160f/161f)
1. Remove the Right Cover.
☞ 32
2. Remove the Rear Cover.
☞ 32
3. Remove the PCL Board. (bizhub 161/161f only)
☞ 35
52
4980D055AA
4980D056AA
4137U003AA
Confidential – for internal use only, do not distribute
Field Service Ver. 1.0 Apr. 2005
4. Unplug one connector on the Con-
troller/Mechanical Control Board.
5. Remove the Relay Harness.
6. Remove the screw, and then remove
the Mechanical Counter.