13. Service Mode (bizhub 160f/bizhub 161f)
I.
TX LEVEL
Functions/Use
• PSK/FSK signal output level.
Setting/Procedure • The default setting is "-9 dBm."
J. RX LEVEL
Functions/Use
• Reception sensitivity level.
Setting/Procedure • The default setting is "-43 dBm."
K. DTMF LEVEL
Functions/Use
• Dual tone output level.
Setting/Procedure • The default setting is "-9 dBm."
L. CNG LEVEL
Functions/Use
• Calling tone output level.
Setting/Procedure • The default setting is "-11 dBm."
M. CED LEVEL
Functions/Use
• Answer tone output level.
Setting/Procedure • The default setting is "-11 dBm."
N. ECM MODE
Functions/Use
• Select error correction mode.
Setting/Procedure • The default setting is "ON."
O. CODING SCHEME
Functions/Use
• Select compression method in TX/ RX mode.
Setting/Procedure • The default setting is "JBIG."
• Select compression method in TX/ RX mode.
130
-2 dBm
-3 to -8 dBm
-36 dBm
-37 to -42 dBm
-2 dBm
-3 to -8 dBm
-2 dBm
-3 to -10 dBm
-2 dBm
-3 to -10 dBm
"ON"
: When an error occurs during communication, re-send the frame
where the error occurs.
OFF
: Any error is ignored during communication.
"JBIG" : The most complex compression method that generates the
smallest code than any of following ones.
MMR : A compression method.
MR
: A compression method.
MH
: The simplest compression method.
Confidential – for internal use only, do not distribute
Field Service Ver. 1.0 Apr. 2005
"-9 dBm"
-10 to -16 dBm
"-43 dBm"
-44 to -48 dBm
"-9 dBm"
-10 to -16 dBm
"-11 dBm"
-12 to -16 dBm
"-11 dBm"
-12 to -16 dBm
-17 dBm
-49 dBm
-17 dBm
-17 dBm
-17 dBm