Dip Switch Sw1 Settings - Sekonic SR-1800 Operating Manual

Optical mark reader
Table of Contents

Advertisement

SR-1800
DIP Switch SW1 Settings
3
Configure RS-232C port communication format and other settings.
CAUTION
· Be careful when configuring settings. Communication errors will occur if settings are
incorrect.
· Make sure the power is off when configuring settings.
· DIP switch 1-6 (SW1-6) is the back side reader setting, unrelated to the RS-232C settings.
It is set to ON for double-sided specification. Meanwhile, it is set to OFF for single-sided
specification.
NO.
NO.
: Indicates the factory settings.
No.
Contents of setting
1
Character bit length
2
Parity
3
Parity
4
Stop bit length
5
Code acceptance status
6
Back side reading
7
Flow control
8
Flow control
Note 1: According to the setting of "Code Acceptance Status," it is possible to ignore the
ASCII codes below when processing commands and data received by the device.
Depending on the computers that are connected and programs used, it may be
necessary to configure this setting.
Codes ignored: 20H, 0AH, 7FH, 1AH

OFF
OFF
ON
ON
ON/OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Explanation
8
7
Absent (Non )
Present (Valid)
Odd
Even.
1
2
All codes are accepted.
(See Note. 1)
For double-sided specification
For single-sided specification
Enabled
Disabled
RS/CS
Xon-Xoff