Connector
Pin
TB
TB1 LIVE
Connected to
TB2 NEUTRAL
AC inlet and
main power
TB3 LIVE(SW)
switch
TB4 LIVE(SW)
YC1
1
+5V2
Connected to
2
+5V2
main PWB
3
+5V2
4
+5V2
5
+5V2
6
+5V2
7
+5V2
8
GND
9
GND
10
GND
11
GND
12
GND
13
GND
14
GND
15
SLEEP
YC2
1
+24V2
Connected to
2
+24V2
engine PWB
3
GND
4
GND
5
+24VIL2
6
GND
7
GND
8
GND
9
GND
10
+24VIL1
11
+24VIL1
12
+24VIL1
Signal
I/O
I
120 V AC
220-240 V AC
I
120 V AC
220-240 V AC
O
120 V AC
220-240 V AC
I
120 V AC
220-240 V AC
O
5 V DC
O
5 V DC
O
5 V DC
O
5 V DC
O
5 V DC
O
5 V DC
O
5 V DC
-
-
-
-
-
-
-
-
-
-
-
-
-
-
I
0/3.3 V DC
O
24 V DC
O
24 V DC
-
-
-
-
O
24 V DC
-
-
-
-
-
-
-
-
O
24 V DC
O
24 V DC
O
24 V DC
Voltage
AC power input
AC power input
AC power output to MSW
AC power input from MSW
5 V DC power output to MPWB
5 V DC power output to MPWB
5 V DC power output to MPWB
5 V DC power output to MPWB
5 V DC power output to MPWB
5 V DC power output to MPWB
5 V DC power output to MPWB
Ground
Ground
Ground
Ground
Ground
Ground
Ground
Sleep signal: On/Off
24 V DC power output to EPWB
24 V DC power output to EPWB
Ground
Ground
24 V DC power output to EPWB
Ground
Ground
Ground
Ground
24 V DC power output to EPWB
24 V DC power output to EPWB
24 V DC power output to EPWB
2-3-16