(3) Detaching and refitting the registration roller
Procedure
1. Open the right cover 1
(See page 1-5-11).
2. Remove the conveyning unit.
(See page 1-5-39)
3. Release four hooks and then remove
the feed guide A from the conveying
unit.
4. Release eight hooks and then remove
the duplex conveying guide from the
conveying unit.
Feed guide A
Conveying unit
Figure 1-5-20
Conveying unit
Duplex
conveying guide
Hooks
Figure 1-5-21
1-5-13
2MW/2MX
Hooks
Hooks
Hooks