Furnace - Propane Gas - Winnebago Solei User Manual

Table of Contents

Advertisement

SECTION 4 –
APPLIANCES AND SYSTEMS
• Lift handle straight out to open P-T valve
when water heater is cold.
-Typical View
4. Let the handle of the P-T valve snap shut.
5. Close the faucet and turn on the water supply
before switching the water heater on.
Manually operate the pressure temperature
relief valve at least once a year.
NOTE: If your water heater is equipped with the
motoraid system, it uses an extension
from the engine cooling system to heat
water in the water heater while driving.
The engine cooling system must also be
cold before opening the pressure-
temperature relief valve. See "Motoraid
Water Heater" for more information.
FURNACE – PROPANE GAS
To Start Up
1. Open the Propane Gas Tank valve by turning
fully "counter-clockwise".
4-8
Thermostat Switch
• Move to Heat or Gas
position for furnace
operation
-Typical View
2. Slide the Thermostat switch from Off to Heat
and press the Temp Selector button (up/down
arrows) until the desired temperature is shown
on the display.
3. The furnace fan should start to blow
immediately after setting the thermostat.
4. After approximately 30 seconds, the furnace
burner should light.
5. The furnace should now cycle off and on
automatically as the thermostat demands just
like a household furnace.
NOTE: If heat does not come out of the heat
ducts after a minute or so, the burner is
not lit.
Turn the thermostat off for 3-5 minutes,
ensure Propane Gas Tank valve is open
and tank is not empty, then repeat Steps
2-4.
If the furnace will not light after three
attempts, go to "Shut Down" steps and
contact your dealer or a local RV service
center for repair.
To Shut Down
1. Slide Thermostat switch to the Off position.
2. Close propane tank valve if coach will be
stored for a period of time.
Temp Selector
• Press up or
down to select
temperature