SECTION 10 –
SLIDEOUT ROOMS AND LEVELING
(5) - EXCESSIVE MOTOR CURRENT.
High amperage (also indicated by one side of
slideout room continually stalling).
(6) - MOTOR SHORT CIRCUIT. Motor or
wiring to motor has shorted out.
(8) - HALL SIGNAL NOT PRESENT.
Encoder is not providing a signal. This is
usually a wiring problem.
(9) - HALL POWER SHORT TO
GROUND. Power to encoder has been
shorted to ground. This is usually a wiring
problem.
NOTE: When an error code is present, the
slideout control panel needs to be reset.
Operating the Extend/Retract switch will
reset the slideout control panel. Operate
the Extend/Retract switch again for
normal operation.
Manual Override
In the event that the slideout room fails to
retract and manual operation is required:
Locate the slideout control panel (located in
driver side compartment).
Press the Mode button 6 times, quickly. Press
a 7th time and hold for approximately 5
seconds.
Red and green LED lights will begin to flash,
confirming the override mode.
Release Mode button.
Use the slideout control switch (located inside
the coach) to retract the room.
NOTE: If slideout room fails to retract using the
Manual Override method, see "Slideout
Emergency Retraction" elsewhere in this
section.
Further Information
See the slideout room operating guide
included in your InfoCase for further instructions
and troubleshooting information.
10-4
SLIDEOUT ROOM
TROUBLESHOOTING (POWER
GEAR
) IN WALL SLIDEOUT
®
–If Equipped
Battery Voltage or Circuit Breaker
Problems
If the slideout room will not work:
Turn the Chassis Battery Disconnect switch
OFF (leave off for 20 seconds) and then turn
ON again. This will, in many cases, reset
power to the slideout system.
he chassis battery may be low on charge.
Press and Hold the Battery Boost switch
(located on the dash) while pressing the
interior slideout control switch. This
momentarily connects the house batteries to
assist in slideout room operation.
The circuit breaker may be tripped. The
circuit breaker, labeled "Slideout Power" is
located on a panel on an interior wall of the
passenger side storage compartment just
behind or ahead of the entrance door.
Problems Retracting or Extending
the Room
• Fault Code
LED
Slideout Control Box
(Located in a driver or passenger side
compartment, depending on model)
-Remove panel to access
If an error is detected on your slide system, the
LED light on the control panel will blink an error
code. If an error code appears, see the In Wall