Pressure-Temperature Relief Valve - Winnebago Solei User Manual

Table of Contents

Advertisement

Gas Water Heater Switch
(Located on Systems Monitor Panel)
For Electric Operation
Turn on the Water Heater electric element
switch. The shoreline must be connected or
generator running for electric operation.
Electric Water Heater Switch
(Typically located near Systems
Monitor Panel)
For Quick Recovery Operation
(Dual Heating)
Turn On both Water Heater switches - the gas
one on the monitor panel and the electric one.
This will help reheat the water heater tank more
quickly than a single source would alone. Use
this mode when you are using a larger than
normal volume of hot water.
Further Information
See the Water Heater manufacturer's
operation manual provided in your InfoCase for
complete operating instructions, safety warnings,
and maintenance information.
APPLIANCES AND SYSTEMS
PRESSURE-TEMPERATURE
RELIEF VALVE
On occasion, water may be seen seeping from
the water heater pressure temperature relief
valve. This is no cause for repair or replacement
of the valve.
Water Heater Exterior Service Access
-Typical View
Normally there is an air gap at the top of the
water heater tank, which acts as a pressure buffer.
In time, however, heated water may expand and
fill this air gap, causing a slight increase in water
pressure. This may cause the P-T valve to "weep"
until the air gap is manually replaced.
CAUTION
Hot water can escape from tank causing
injury. Operate this valve only when the
tank water is cold.
To Replace the Air Gap:
1. Turn off the Water Heater switch and
incoming water supply (city water and/or
demand pump).
2. Open a faucet in the motorhome to relieve
water pressure.
3. Pull the handle of the P-T valve straight out
and allow water to flow until it stops.