3. 2. 7
User Mode 6: Warm Sleep Timer Setting Mode
Please Set the Touchscreen - "?"
Do not change this setting.
It is possible to change the timer for the Warm Sleep function on the User Interface (UI).
Reference
1. The purpose of Warm Sleep Mode is to reduce power consumption by reducing the
temperature of heater. The temperature of the heater unit is about 140 degrees
Centigrade (284 degrees Fahrenheit) when the KIP 5000 is ready. But if the system is not
in use for an extended period, it is advised to reduce power consumption by reducing the
temperature of the heater (Temperature is kept at about 120 degrees Centigrade (248
degrees Fahrenheit).
The Warm Sleep Mode will be automatically cancelled when a print or copy job is sent.
However, it takes a few moments for the system to recover from the Warm Sleep Mode
because it must raise the temperature back up to about 140 degrees Centigrade (284
degrees Fahrenheit) (Print does not start until the KIP 5000 gets ready).
2. When both the Cold Sleep Function and the Warm Sleep Function are effective, their
functions work as follows; (Both timers start simultaneously.) For information on the Warm
Sleep Function, refer to page 3-11 to 3-12.
<Example 1>
When the Warm Sleep Timer is set to 15 minutes and the Cold Sleep Timer is set to 30
minutes, the printer will go into warm sleep mode 15 minutes after printing. The printer will
go into the Cold Sleep Mode 15 minutes after the printer goes into Warm Sleep Mode.
<Example 2>
When the Warm Sleep Timer is set to 30 minutes and the Cold Sleep Timer is set to 15
minutes, the printer will go into Cold Sleep Mode 15 minutes after printing. In this case,
the Warm Sleep Function is ineffective.