Selection Of Peripheral Devices - Mitsubishi Electric FR-V520-1.5K to 55K Instruction Manual

Vector inverter
Hide thumbs Also See for FR-V520-1.5K to 55K:
Table of Contents

Advertisement

Basic configuration and connection
of peripheral devices
Caution
• Do not fit capacitive equipm ent such as power factor correction capacitor, radio noise filter (FR-BIF
option) or surge suppressor to the output side of the inverter. This will cause the inverter to trip or power
factor correction capacitor and surge suppressor to be dam aged. If any of the above devices are con-
nected, im mediately rem ove them . If the FR-BIF radio noise filter is connected, switching pow er off during
m otor operation m ay result in "E.UVT". In this case, connect the radio noise filter on the prim ary side of
the m agnetic contactor.
• Electromagnetic wave interference
The input/output (main circuit) of the inverter includes harmonic components, which may interfere with
the communication devices (such as AM radios) used near the inverter. In this case, install the FR-BIF
optional radio noise filter (for use in the input side only) or FR-BSF01 or FR-BLF line noise filter to mini-
mize interference.
1.1.2

Selection of peripheral devices

Check the capacities of the motor applicable to the inverter you purchased. Refer to the list below and prepare
appropriate peripheral devices.
200V class
Motor
Applicable
Output
Inverter
(kW)
Type
1.5
FR-V520-1.5K
2.2
FR-V520-2.2K
3.7
FR-V520-3.7K
5.5
FR-V520-5.5K
7.5
FR-V520-7.5K
11
FR-V520-11K
15
FR-V520-15K
18.5
FR-V520-18.5K
22
FR-V520-22K
30
FR-V520-30K
37
FR-V520-37K
45
FR-V520-45K
55
FR-V520-55K
400V class
Motor
Applicable
Output
Inverter
(kW)
Type
1.5
FR-V540-1.5K
2.2
FR-V540-2.2K
3.7
FR-V540-3.7K
5.5
FR-V540-5.5K
7.5
FR-V540-7.5K
11
FR-V540-11K
15
FR-V540-15K
18.5
FR-V540-18.5K
22
FR-V540-22K
30
FR-V540-30K
37
FR-V540-37K
45
FR-V540-45K
55
FR-V540-55K
*1. Select the NFB type according to the power supply capacity.
No-fuse Breaker
*1
or Earth Leakage Cir-
(NFB
)
cuit Breaker (ELB
With power factor
Standard
improving reactor
30AF 15A
30AF 15A
30AF 20A
30AF 15A
30AF 30A
30AF 30A
50AF 50A
50AF 40A
100AF 60A
50AF 50A
100AF 75A
100AF 75A
225AF 125A
100AF 100A
225AF 150A
225AF 125A
225AF 175A
225AF 150A
225AF 225A
225AF 175A
400AF 250A
225AF 225A
400AF 300A
400AF 300A
400AF 400A
400AF 350A
No-fuse Breaker
*1
or Earth Leakage Cir-
(NFB
)
cuit Breaker (ELB
W ith power factor
Standard
improving reactor
30AF 10A
30AF 10A
30AF 15A
30AF 10A
30AF 20A
30AF 15A
30AF 30A
30AF 20A
30AF 30A
30AF 30A
50AF 50A
50AF 40A
100AF 60A
50AF 50A
100AF 75A
100AF 60A
100AF 100A
100AF 75A
225AF 125A
100AF 100A
225AF 150A
225AF 125A
225AF 175A
225AF 150A
225AF 200A
225AF 175A
3
Power Factor
Power Factor
Improving AC
Improving DC
)
Reactor
FR-BAL-1.5K
FR-BEL-1.5K
FR-BAL-2.2K
FR-BEL-2.2K
FR-BAL-3.7K
FR-BEL-3.7K
FR-BAL-5.5K
FR-BEL-5.5K
FR-BAL-7.5K
FR-BEL-7.5K
FR-BAL-11K
FR-BEL-11K
FR-BAL-15K
FR-BEL-15K
FR-BAL-22K
FR-BEL-18.5K
FR-BAL-22K
FR-BEL-22K
FR-BAL-30K
FR-BEL-30K
FR-BAL-37K
FR-BEL-37K
FR-BAL-45K
FR-BEL-45K
FR-BAL-55K
FR-BEL-55K
Power Factor
Power Factor
Improving AC
Improving DC
)
Reactor
FR-BAL-H1.5K
FR-BEL-H1.5K
FR-BAL-H2.2K
FR-BEL-H2.2K
FR-BAL-H3.7K
FR-BEL-H3.7K
FR-BAL-H5.5K
FR-BEL-H5.5K
FR-BAL-H7.5K
FR-BEL-H7.5K
FR-BAL-H11K
FR-BEL-H11K
FR-BAL-H15K
FR-BEL-H15K
FR-BAL-H22K
FR-BEL-H18.5K
FR-BAL-H22K
FR-BEL-H22K
FR-BAL-H30K
FR-BEL-H30K
FR-BAL-H37K
FR-BEL-H37K
FR-BAL-H45K
FR-BEL-H45K
FR-BAL-H55K
FR-BEL-H55K
Magnetic
Contactor
Reactor
(MC)
S-N10
S-N11, N12
S-N20
S-N25
S-N35
S-N50
S-N65
S-N80
S-N95
S-N125
S-N150
S-N180
S-N220
Magnetic
Contactor
Reactor
(MC)
S-N10
S-N11, N12
S-N20
S-N20
S-N20
S-N20
S-N25
S-N35
S-N50
S-N65
S-N80
S-N80
S-N125