Mitsubishi Electric FR-V520-1.5K to 55K Instruction Manual page 70

Vector inverter
Hide thumbs Also See for FR-V520-1.5K to 55K:
Table of Contents

Advertisement

Name
You can turn on/off the inverter output.
Remote output
495
0: Non-latch
selection
1: Latch
496 Remote output data 1
You can set the output signal data of the inverter.
0 to 4095
497 Remote output data 2
Control system
800
0 to 5, 20
selection
You can select the torque characteristic when choosing the motor provided with PLG.
Torque characteristic
801
0: Cycle
selection
1: Continuous
You can select zero speed control or servo lock when the LX signal turns on at a stop.
Pre-excitation
802
0: Zero speed control
selection
1: Servo lock
Constant output
You can select how to provide a torque command in the constant output region.
region torque
803
0: Constant output reference
characteristic
1: Constant torque reference
selection
Select the torque command right.
Torque command
0: No. 3 terminal analog input
804
right selection
1: Digital input from parameter (Pr. 805, Pr. 806)
2: Pulse train command input (when the FR-V5AP is fitted)
Torque command
You can set the torque command value in the parameter. (RAM)
805
value (RAM)
600 to 1400%
Torque command
You can set the torque command value in the parameter. ( RAM, E
value
806
600 to 1400%
2
(RAM, E
PROM)
You can select the speed restriction command input for torque control.
Speed restriction
0: Same as speed setting for speed control
807
selection
1: Control restrictions for individual rotation directions
2: No. 1 terminal analog input
Set the speed restriction in forward rotation direction individually according to the
Forward rotation
808
rotation direction.
speed restriction
0 to 3600r/min
Set the speed restriction in reverse rotation direction individually according to the
Reverse rotation
809
rotation direction.
speed restriction
0 to 3600r/min, 9999
Torque restriction
Set whether to make torque restriction using internal parameter values or analog
810
input method
voltage. (0: Internal, 1: External)
selection
Function list (Extended function
Outline
2
PROM)
66
parameters)
At-a-glance Guide to Func-
tions
" " " " : Usable function
×: Unusable function
Cus-
* : Functions that can be used
Factory
tomer
for param eter-set position con-
Setting
Set-
trol
ting
Vector Control
Speed
Torque
control
control
" " " "
" " " "
0
" " " "
" " " "
0
" " " "
" " " "
0
" " " "
" " " "
0
" " " "
" " " "
1
" " " "
×
0
" " " "
" " " "
0
" " " "
×
0
" " " "
×
1000%
×
" " " "
1000%
×
" " " "
0
" " " "
×
1 50 0r/m in
×
" " " "
9999
" " " "
×
0
Position
control
" " " "
" " " "
" " " "
" " " "
" " " "
" " " "
" " " "
×
×
×
×
×
×
" " " "
5