Easy gain tuning

4.5 Easy gain tuning
The ratio of the load inertia to the motor inertia (load inertia moment ratio) is estimated in real time from the
torque command and speed during motor operation to automatically set the optimum gains for speed control/
position control from that ratio and response level setting.
4.5.1
Parameter
Parameter
Name
Easy gain tuning
818
response level setting
Easy gain tuning
819
selection
4.5.2
Easy gain tuning execution procedure
(1) Setting the response level in
Pr. 818 "easy gain tuning
response level setting"
Refer to the diagram on the right and
set the response level.
Increasing
the value
trackability to the command, but too
high value will generate vibration. The
relationship between the setting and
response level are shown on the right.
(2) Setting easy gain tuning enable in Pr. 819 "easy gain tuning selection"
Pr. 819 Setting
• Easy gain tuning is invalid.
0
• None of the load inertia ratio, position control gain and speed control gain values are updated.
(factory setting)
• Easy gain tuning is valid.
• Each control gain is automatically set from the load inertia ratio estimated during acceleration/
1
deceleration operation and the Pr. 818 "easy gain tuning response level setting" value.
• Pr. 880 "load inertia ratio" is used as the initial value of the load inertia ratio for tuning. Estimated
value is set in Pr. 880 during tuning.
• Used when the load inertia ratio cannot be estimated well due to load disturbance and such or when
the load inertia ratio is known in advance, for example. At this time, the load inertia ratio is not
2
estimated and each control gain is automatically set from the Pr. 880 "load inertia ratio" setting and
Pr. 818 "easy gain tuning response level setting" value.
(3) Start signal
Press
or
FWD
REV
(The operation command for external operation is the STF or STR signal.)
REMARKS
When "1 or 2" is set in Pr. 819 "easy gain tuning selection" and then returned to "0", tuning results which are automatically set
in each parameter remain unchanged.
Factory
Setting
2
0
Pr. 818 setting
Response level
Guideline of machine
resonance frequency
(Hz)
will
improve
to estimate the load inertia ratio or calculate gain any time.
Setting Range
Set the response level.
1 to 15
1: Slow response to 15: Fast response
0: No tuning
1: With load estimation, with gain calculation
0, 1, 2
2: Manual load input (Pr. 880), with gain
calculation
1
2
3
4
5
6
7
Slow
response
8
10 12 15 18 22 28 34 42
Large conveyor
Arm robot
Description
43
Remarks
8
9
10
11
12
13
14
15
Middle
Fast
response
response
52
64
79
98
122 150
General machine
tool, conveyor
Precision
machine tool