Mitsubishi Electric FR-V520-1.5K to 55K Instruction Manual page 17

Vector inverter
Hide thumbs Also See for FR-V520-1.5K to 55K:
Table of Contents

Advertisement

Connection diagram, PLG cable, PU
connector
(2) Setting the number of PLG pulses and PLG rotation direction
Set the following parameters according to the PLG specification.
Parameter
Name
851
Number of PLG pulses
852
PLG rotation direction
! The rotation direction monitor of the parameter unit displays the rotation direction of the encoder,
refer to the following table.
Pr. 852 Setting
Relationship between the motor and PLG
0
PLG
Forward rotation is clockwise rotation
when viewed from A.
1
PLG
PLG
(factory setting)
Forward rotation is counterclockwise rotation
when viewed from A.
REMARKS
• By setting "1" in Pr.160 "extended function selection", Pr. 851 and Pr. 852 are made valid.
• The number of PLG pulses should be between 1000 and 4096.
!
When using a conventional motor and a PLG cable (FR-VCBL/FR-JCBL), refer to the
Instruction Manual (detailed).
Factory Setting
Setting Range
2048
0 to 4096
1
0, 1
CW
A
CCW
A
A
13
Remarks
Extension
mode

Advertisement

Table of Contents
loading

Table of Contents