Mitsubishi Electric FR-V520-1.5K to 55K Instruction Manual page 65

Vector inverter
Hide thumbs Also See for FR-V520-1.5K to 55K:
Table of Contents

Advertisement

Function list (Extended function
parameters)
Name
168
Maker setting parameters. Do not make setting.
169
Actual operation hour
171
You can clear the actual operation hour meter.
meter clear
You can select the following input signals.
0: RL (multi-speed low-speed operation command) → Pr. 180 factory setting
DI1 terminal function
180
1: RM (multi-speed middle-speed operation command) → Pr. 181 factory setting
selection
2: RH (multi-speed high-speed operation command) → Pr. 182 factory setting
3: RT (second function selection) → Pr. 183 factory setting
5: JOG (jog operation selection)
8: REX (multi-speed 15 speeds selection)
DI2 terminal function
181
9: X9 (third function selection)
selection
10: X10 (FR-HC,FR-CV connection (inverter run enable signal))
11: X11 (FR-HC connection (instantaneous power failure detection)
12: X12 (PU operation external interlock)
14: X14 (PID control valid)
DI3 terminal function
182
15: BRI (brake release completion signal)
selection
16: X16 (PU operation-external operation switching)
20: X20 (S-pattern acceleration/deceleration C switching terminal)
22: X22 (orientation command)
23: LX (pre-excitation/servo on)
DI4 terminal function
24:MRS(output stop)
183
selection
25: STOP (start self-holding selection)
26: MC (control mode switching)
27: TL (torque restriction selection)
42: X42 (torque bias selection 1)
STR terminal function
43: X43 (torque bias selection 2)
187
selection
44: X44 (P control selection (P/PI control switching))
9999: No function (STR when set in Pr. 187)
You ca n select the follo w in g output signals.
0 (positive logic) → Pr. 190 factory setting, 100 (negative logic): RUN (inverter running)
1 (positive logic) → Pr. 191 factory setting, 101 (negative logic): SU (up to speed)
2 (positive logic) → Pr. 192 factory setting, 102 (negative logic): IPF (instantaneous
DO1 terminal function
190
power failure or undervoltage)
selection
3 (positive logic), 103 (negative logic) : OL (overload alarm)
4 (positive logic), 104 (negative logic) : FU (output speed detection)
5 (positive logic), 105 (negative logic) : FU2 (second output speed detection)
6 (positive logic), 106 (negative logic) : FU3 (third output speed detection)
7 (positive logic), 107 (negative logic) : RBP (regenerative brake prealarm)
8 (positive logic), 108 (negative logic) : THP (electronic thermal alarm prealarm)
10 (positive logic), 110 (negative logic) : PU (PU operation mode)
11 (positive logic), 111 (negative logic) : RY (inverter operation ready)
12 (positive logic), 112 (negative logic) : Y12 (output current detection)
DO2 terminal function
13 (positive logic), 113 (negative logic) : Y13 (zero current detection)
191
selection
14 (positive logic), 114 (negative logic) : FDN (PID lower limit)
15 (positive logic), 115 (negative logic) : FUP (PID upper limit)
16 (positive logic), 116 (negative logic) : RL (PID forward/reverse rotation output)
20 (positive logic), 120 (negative logic) : BOF (brake opening request)
25 (positive logic), 125 (negative logic) : FAN (fan failure output)
26 (positive logic), 126 (negative logic) : FIN (fin overheat prealarm)
27 (positive logic), 127 (negative logic) : ORA (orientation completion)
30 (positive logic), 130 (negative logic) : Y30 (forward rotation output)
31 (positive logic), 131 (negative logic) : Y31 (reverse rotation output)
32 (positive logic), 132 (negative logic) : Y32 (regenerative status output)
DO3 terminal function
192
33 (positive logic), 133 (negative logic) : RY2 (operation ready 2)
selection
34 (positive logic), 134 (negative logic) : LS (low speed output)
35 (positive logic), 135 (negative logic) : TU (torque detection)
36 (positive logic), 136 (negative logic) : Y36 (in-position)
37 (positive logic), 137 (negative logic)) : MT (maintenance timer output)
40 (positive logic), 140 (negative logic) : Y40:(trace status)
41 (positive logic), 141 (negative logic) : FB (speed detection)
42 (positive logic), 142 (negative logic): FB2 (second speed detection)
43 (positive logic), 143 (negative logic) : FB3 (third speed detection)
44 (positive logic), 144 (negative logic) : RUN2 (second inveter operating)
A,B,C terminal
96 (positive logic), 196 (negative logic): REM (remote output)
195
function selection
97 (positive logic), 197 (negative logic) : ER (minor fault output 2)
98 (positive logic), 198 (negative logic) : LF (minor fault output)
99 (positive logic) → Pr. 195 factory setting, 199 (negative logic): ABC (alarm output)
9999: No function
Outline
61
At-a-glance Guide to Func-
tions
" " " " : Usable function
×: Unusable function
Cus-
* : Functions that can be used
Factory
tomer
for param eter-set position con-
Setting
Set-
trol
ting
Vector Control
Speed
Torque
control
control
" " " "
" " " "
0
" " " "
" " " "
0
" " " "
" " " "
1
" " " "
" " " "
2
" " " "
" " " "
3
" " " "
" " " "
9999
" " " "
" " " "
0
" " " "
" " " "
1
" " " "
" " " "
2
" " " "
" " " "
99
Position
control
" " " "
" " " "
" " " "
" " " "
" " " "
" " " "
" " " "
" " " "
" " " "
" " " "